In order to provide the best functioning of the device, it is necessary to comply with the
following simple requirements:
- Switch off the device, when not in use
- Clean the hopper and stacker with a clean dry cloth. Sensors can cause errors when
dirty.
It is recommended to carry out preventive measures, including partial disassembling of
the counter each 30 days by an engineer in the service center.
13
System errors (appears on the display immediately after you turn on the counter)
Code
The hopper sensor is blocked by
E5
banknotes or dirt
The stacker sensor is blocked by
E6
banknotes or dirt
The left counting sensor is
E2
blocked by dirt or out of operation
The right counting sensor is
E1
blocked by dirt or out of operation
If other errors are indicated when switching on the counter, apply to a service center.
Error codes during counting process:
Code
Banknotes have passed through
EC
without being properly separated
1. The device has detected a
banknote with a different density
Ed
than expected,
2. DEN level is very high.
1. The banknote has exhibited
suspicious UV properties
CF1
2 UV level is very high
14
Maintenance
Message
Message
1. Remove banknotes from the stacker and repeat the
counting procedure
2. Adjust the slot, see Table 12
1. Remove banknotes from the stacker and repeat the
counting procedure
2. Adjust the slot, see Table 12
3. Set a lower DEN sensitivity level, see Table 11
1. Remove the suspicious banknote (lying on the top).
Remove banknotes from the stacker and repeat the
counting procedure.
2. Use additional verification methods for the
suspicious banknote, for example, viewing UV or IR
detectors.
3. Set a lower DEN sensitivity level under cl. 11.

Error codes

Reason
Remove banknotes from the hopper and clean it
Remove banknotes from the stacker and clean it
Clean the sensor or replace ut
Clean the sensor or replace ut
Reason

Werbung