5. Before starting

Important!
b
Before you connect the appliance to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
b
The appliance may only be connected to a shock-
proof socket.
5.1 Assembling the appliance
Fitting the appliance head (Fig. 5/3)
The appliance head (3) is fastened to the container
(8) by the locking hook (7). To remove the appliance
head (3), open the locking hook (7) and remove the
appliance head (3). When fitting the appliance head
(3), make sure that the locking hook (7) locks into
place correctly.
Fitting the wheels (Fig. 3/14)
Fit the wheels in accordance with Fig. 4.
5.2 Fitting the filter
Important!
Never use the wet and dry vacuum cleaner without a
filter.
Check that the filter is securely fitted at all times.
Fitting the foam filter (Fig. 6/16)
For wet vacuuming, slip the supplied foam filter (16)
over the filter basket (Fig. 2/4). The pleated filter (15)
already fitted upon delivery is not suitable for wet
vacuuming.
Fitting the pleated filter (Fig. 7/15)
For dry-vacuuming, slip the pleated filter (Fig. 3/15)
over the filter basket (Fig. 2/4). The pleated filter (15)
is suitable for dry-vacuuming only.
Fitting the dirt bag
(not supplied)
For vacuuming fine, dry dirt it is recommended that
you also fit the dirt bag. This will ensure that the
pleated filter (15) does not fill up so quickly and
therefore help the vacuuming power last longer. In
addition, it makes it easier to dispose of the dust. Slip
the dirt bag over the vacuuming hole. The dirt bag is
suitable for dry-vacuuming only.
5.3 Fitting the suction hose (11)
Connect the suction hose (11) to the corresponding
connector on the wet and dry vacuum cleaner,
depending on the application required.
8
25.06.2007
8:50 Uhr
Seite 8
Vacuuming
Connect the suction hose (11) to the suction hose
connector (9).
Blowing
Connect the suction hose (11) to the blow connector
(10).
To extend the suction hose (11) you can attach one
or more of the elements which make up the 3-part
suction tube (12) to the suction hose (11).
5.4 Suction nozzles
Dual-purpose nozzle (13)
The dual-purpose nozzle (13) is for vacuuming solids
and liquids over medium to large areas.

6. Operation

6.1 ON/OFF switch (Fig. 2/2)
Switch position 0:
Off
Switch position I:
Normal operation
Switch position II:
Automatic mode
6.2. Dry vacuuming
For dry-vacuuming, use the pleated filter (15). In
addition, you can also fit the dirt bag. (see point 5.2)
Check that the filter is securely fitted at all times.
6.3 Wet vacuuming
For wet-vacuuming, use the foam filter (16) (see point
5.2).
Check that the filter is securely fitted at all times.
Important!
When wet vacuuming, the floating safety switch (5)
turns off the wet and dry vacuum cleaner
automatically when the maximum level is reached.
Important!
The wet and dry vacuum cleaner is not suitable for
the vacuuming of combustible liquids.
For wet vacuuming, use only the supplied foam filter.
6.4 Automatic mode
Connect the power cable on your electric tool to the
automatic socket-outlet (6) and connect the suction
hose (11) to the extractor connector on your electric
tool. Check that the connections are secure and air-
tight.
You can use the supplied electric tool adaptor (19) to
connect the suction hose (11) to the electric tool. To