Functions during the dive / Functions at the surface

4.10 Safety stop timer

DEPTH
DIVE TIME
STOP
CNS O
%
2
Safety stop
icons
Minutes
Remaining
Seconds
time span

5 Functions at the surface

5.1 End of a dive

DEPTH
DIVE TIME
CNS O
%
2
Depth less than 0.8m (3ft)

5.2 Residual nitrogen bar graph

The segments in the residual nitrogen bar graph will gradually turn off as XP10 follows the offgassing
of your tissues during your surface interval. There is a 1:1 equivalence in the meaning of the segments
between diving and surface. Thus, on a repetitive dive the bar will resume from its status on the surface
just prior to the dive. There are two exceptions however:
the uppermost segment will stay lit until the desaturation time is completely extinguished. This is
done to show that there is desaturation time left and that a dive started at this point will be logged
as a repetitive dive. If the remaining desaturation time is very short, this segment could however at
first disappear during the dive;
during the 24 hours of an SOS-lock, all segments will stay on.

5.3 Desaturation time, No-fly time and No-dive warning

No-fly time
Do not fly icon
No-dive
warning
NO
S
L
O
W
Time of day
Residual nitrogen bar
Ascent to altitude
range 4 prohibited
26
The safety stop timer displays the time span a diver should spend at the
safety stop depth at the end of the dive. The timer is activated by the diver
and counts back from 3 minutes to zero. It can be restarted any number
of times.
The safety stop timer can be activated under the following conditions: depth
< 6.5m (21ft), no-stop display 99 minutes.
Activate the safety stop timer by pressing
backwards and a bookmark will be created in the dive profile. If you press
again, the timer will start again from the full value.
The safety stop timer will switch off automatically if the depth exceeds 6.5m
(21ft) or the no-stop phase is shorter than 99 minutes.
After reaching the surface (<0.8m/3ft) XP10 remains in dive mode for 5
minutes. The delay allows for surfacing for a short period for orientation.
After 5 minutes the dive is closed and it is entered into the logbook. The time
of day is then displayed for 3 minutes, after which the computer turns off.
For the calculations of the desaturation and no-fly time it is assumed
that the diver breathes air while on the surface.
5 minutes after a dive XP10 shows the time of day, the "do not fly time", the
no-dive warning (if applicable), the current altitude range and the prohibited
altitude range (->27).
No-fly time is the time in hours that should pass before a flight and is
displayed and adjusted until the value becomes 0 hours.
Flying while XP10 displays "do not fly" may lead to serious injury or
death from decompression sickness.
. The timer begins to count
! WARNING
! WARNING