Functions during the dive
F
• During an ascent and if the CNS O
partial pressure of oxygen), the audible warning is suppressed.
• During the ascent, the display of the oxygen toxicity is replaced by the ascent rate. If
the ascent is stopped, the display changes back to the indication of the CNS value.
• XP10 will display CNS O

4.8 Nitrogen loading bar graph

The nitrogen loading bar gives a graphical representation of how close to decompression you are. As
you absorb nitrogen during the dive, more and more segments of the bar will light up. Depending on
your depth, the segments can light up more or less rapidly.
1-3 segments (green
area):
you are safely within the
no-stop range.
* Depending on your profile, the no-stop time may drop below 3 minutes before the upper 5 segments are lit. In this case, only those segments
that are lit will flash.
If you have entered decompression, the 6th segment will turn off as soon as you complete your last
decompression obligation to indicate that you are no longer in decompression.

4.9 Decompression information

NO STOP and the no-stop time (minutes) are displayed if no decompression stops are necessary.
DEPTH
DIVE TIME
NO STOP
CNS O
%
2
No-stop time
Nitrogen loading bar
4s
DEPTH
DIVE TIME
NO STOP
CNS O
%
2
No-stop time less
than 1 minute
24
2
% values exceeding 199 % with 199 %.
2
4-5 segments (yellow
area):
you are approaching
decompression. When
the no-stop time drops
below 3 minutes the
5 segments will start
flashing.*
F
• No-stop display "99:" means remaining time of 99 minutes or
more.
• No-stop time is influenced by the water temperature.
If no-stop time drops below 3 minutes, an audible attention signal is
activated, the no-stop value and the nitrogen loading bar begin to
flash. If no-stop time is less than 1 minute, the no-stop display shows
the flashing value "0".
In order to prevent a decompression dive, ascend slowly until the
no-stop time is 5 minutes or more.
Dives that require decompression stops are not recommended.
% value does not increase anymore (due to a lower
! WARNING
! WARNING
6 segments (red
area): you now
have mandatory
decompression
obligation(s) which you
must observe before
reaching the
surface.