Herunterladen Diese Seite drucken

Installation Instructions; Flow Diagram - HANSGROHE Decor Gebrauchsanleitung, Montageanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
2
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- Residue
- Water pressure to low
- Diverter defective
- Hot water limiter incorrectly set
- Crossflow
Assembly see page 4
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 5)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions (see page 6)

Flow diagram

(see page 6)
Rate of flow by 0,3 MPa:
Tub outlet
Shower outlet
Operation (see page 8)
Spare parts (see page 7)
Cleaning
see enclosed brochure
Remedy
- Exchange cartridge
- Exchange cartridge
- Clean converter / grease O-rings
- Increase water pressure
- Exchange diverter
- Set hot water limiter
- Exchange cartridge

Werbung

loading