Specifications
Range
pH
Resolution
Accuracy
Calibration
Buffers
Temperature compensation
ISO-pH
Slope
Zero point (Eo)
Range
mV
Resolution
Accuracy
Calibration
Range
ION
Resolution
Accuracy
Calibration
Range (cc dependent)
Range (cc dependent)
CONDUCTIVITY
Resolution (cc dependent)
Accuracy
Calibration
Standards
Cell constant (cc)
Temperature compensation
Reference temperature
Temperature coefficient
Range lock
Capacitive compensation
Range
RESISTIVITY
Resolution
Range
SALINITY
Resolution
Range
TDS
Resolution
Range
DISSOLVED OXYGEN
Resolution
Accuracy
Calibration
Temperature compensation
Salinity compensation
Air pressure compensation
Range
TEMPERATURE
Resolution
Accuracy
Calibration
Range
AIR PRESSURE
Calibration
Measurement
INPUTS
Temperature
Reminder
CALIBRATION
GLP
LCD
DISPLAY
White backlight
Hold function
Selectable resolution
Real time clock
COMMUNICATION
Interface with computer
Data sets
DATA-LOGGING
Modes
Manual or timed
Interval
Identification number
SECURITY
Password protection
Temperature
AMBIENT CONDITIONS
Humidity
Mains
POWER SUPPLY
Low voltage
Batteries
DIMENSIONS
WxDxH
WEIGHT
Meter
33
33
C6010
C6020
-2...+16 pH
-2...+16 pH
0.001 pH
0.001 pH
0.1% ± 1 digit
0.1% ± 1 digit
1...5 points
1...5 points
9 pre-programmed
9 pre-programmed
5 user specified
5 user specified
-5...+105°C
-5...+105°C
6...8 pH
6...8 pH
80...120%
80...120%
±999 mV
±999 mV
±2000 mV
±2000 mV
0.1 mV
0.1 mV
0.1% ± 1 digit
0.1% ± 1 digit
1 point
1 point
0...2000 mS/cm
0...2000 mS/cm
0.001 µS/cm
0.001 µS/cm
0.5% f.s. of range
0.5% f.s. of range
1...3 points
1...3 points
0.01/0.1/1M KCl
0.01/0.1/1M KCl
3 user specified
3 user specified
0.1/1/10 cm
-1
±30%
0.1/1/10 cm
-5...+105°C
-5...+105°C
20° or 25°C
20° or 25°C
natural waters (EN27888)
natural waters (EN27888)
ü
ü
ü
ü
0...200 MΩ.cm
0...200 MΩ.cm
1 Ω.cm
1 Ω.cm
0...70 ppt
0...70 ppt
0.1 ppt
0.1 ppt
0...100 g/l
0...100 g/l
0.01 mg/l
0.01 mg/l
0...60 mg/l (0...600%)
0.01 mg/l (0.1%)
1% ± 1 digit
1 point
0...50°C
0...40 ppt
600...1300 hPa
-5...+105°C
-5...+105°C
0.1°C
0.1°C
0.3°C
0.3°C
1 point
1 point
600...1300 hPa
1 point
12
BNC, 10
BNC, 10
2 banana, for Pt1000
2 banana, for Pt1000
0...999 h
0...999 h
ü
ü
128x64 pixels
128x64 pixels
ü
ü
ü
ü
ü
ü
ü
ü
USB, insulated
USB, insulated
12000
12000
all (9)
all (9)
ü
ü
1...9999 s
1...9999 s
ü
ü
ü
ü
0...40°C
0...40°C
0...95%, non condensing
0...95%, non condensing
210...250 VAC, 50/60 Hz
210...250 VAC, 50/60 Hz
9...15 VDC
9...15 VDC
4x1.2 V, AA, NiMH
4x1.2 V, AA, NiMH
12x25x5 cm
12x25x5 cm
600 g
600 g
C6030
-2...+16 pH
0.001 pH
0.1% ± 1 digit
1...5 points
9 pre-programmed
5 user specified
-5...+105°C
6...8 pH
80...120%
±999 mV
±2000 mV
0.1 mV
0.1% ± 1 digit
1 point
0.01 ng/l...100 g/l
3 digits
0.5% ± 1 digit
2 points + blank
0...2000 mS/cm
0.001 µS/cm
0.5% f.s. of range
1...3 points
0.01/0.1/1M KCl
3 user specified
-1
±30%
0.1/1/10 cm
-5...+105°C
20° or 25°C
natural waters (EN27888)
ü
ü
0...200 MΩ.cm
1 Ω.cm
0...70 ppt
0.1 ppt
0...100 g/l
0.01 mg/l
0...60 mg/l (0...600%)
0.01 mg/l (0.1%)
1% ± 1 digit
1 point
0...50°C
0...40 ppt
600...1300 hPa
-5...+105°C
0.1°C
0.3°C
1 point
600...1300 hPa
1 point
12
12
BNC, 10
2 banana, for Pt1000
0...999 h
ü
128x64 pixels
ü
ü
ü
ü
USB, insulated
12000
all (9)
ü
1...9999 s
ü
ü
0...40°C
0...95%, non condensing
210...250 VAC, 50/60 Hz
9...15 VDC
4x1.2 V, AA, NiMH
12x25x5 cm
600 g
-1
±30%
C6010 • C6020 • C6030