Herunterladen Diese Seite drucken

Gallagher M1800i Betriebsanleitung Seite 14

Vorschau ausblenden Andere Handbücher für M1800i:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 53
Using The Energizer Controller
Energizer Output and Alarms
The energizer output is the default screen display mode. The zone indicator arrow
is highligh ng the energizer zone (
this case.
The quickscan bargraph display is also indica ng an output voltage of over 7KV.
Voltage Alarm
If the energizer output voltage falls below the alarm level (default 3KV) then the
status LED will fl ash red, the energizer zone indicator will become highlighted and an
internal buzzer will sound on the energizer. The buzzer can be muted by pressing any
key on the controller, except when there is a sudden increase in fence load. In this
situa on the buzzer will me out a er 15 minutes (if the energizer has not already
been turned off ).
Status LED
fl ashes red
14
Gallagher 3E2489 M1800i M2800i Energizer User Manual
) and the energizer output voltage is 7.3KV in
Controller showing the energizer opera ng normally
Controller showing the energizer in output alarm

Quicklinks ausblenden:

Werbung

loading

Diese Anleitung auch für:

M2800i