Herunterladen Inhalt Inhalt Diese Seite drucken

Analogue Output; Setting Ranges For The Switch Outputs - HYDAC EDS 3000 Bedienungsanleitung

Elektronischer druckschalter
Vorschau ausblenden Andere Handbücher für EDS 3000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Example for switching output 1 (normally closed and normally open function):
Normally open function
Normally closed function
Abbreviations:
NOTE:
The window function only works properly (switching on and off) if all switch values
(including the safety margin) are greater than 0 bar and smaller than the nominal
pressure range.
7.2

ANALOGUE OUTPUT

Analogue output signal:
7.3

SETTING RANGES FOR THE SWITCH OUTPUTS

Measuring
range
in bar
- 1 .. 1
0 .. 1
0 .. 2.5
0 .. 6
0 .. 10
0 .. 16
0 .. 40
0 .. 100
0 .. 250
0 .. 400
0 .. 600
* All ranges given in the table can be set in the increment grid.
10
On
Off
On
Off
On
Off
"FH1", "FH2"
= upper switch value 1 / upper switch value 2
"FL1", "FL2"
= lower switch value 1 / lower switch value 2
"FNO"
= Normally open when window function is active
"FNC"
= Normally closed when window function is active
4 to 20 mA or 0 to 10 V
(Can be set in the "Basic settings" menu).
Lower limit
Upper limit
of RP / FL
of SP / FH
in bar
in bar
-0.98
1.00
0.010
1.000
0.025
2.500
0.06
6.00
0.10
10.00
0.20
16.00
0.4
40.0
1.0
100.0
2.5
250.0
4
6
Safety zone
On
Safety zone
Off
Minimum distance
between RP and
SP or FL and FH
0.02
0.010
0.025
0.06
0.10
0.20
0.4
1.0
2.5
400
4
600
6
Reverse switch point
Switch point
Switch point
Reverse switch point
Increment
in bar
0.01
0.002
0.005
0.01
0.02
0.05
0.1
0.2
0.5
1
1

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis