Herunterladen Inhalt Inhalt Diese Seite drucken

Symbols Used In The Manual - Crown CT15212 Original Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
• Note that when you operate a power tool, please
hold the auxiliary handle correctly, which is helpful
when controlling the power tool� Therefore, proper
holding can reduce the risk of accidents or injuries�
Service
• Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the power tool
is maintained�
• Follow instruction for lubricating and changing ac-
cessories�
Special safety warnings
Hold power tool by insulated gripping surfaces,
when performing an operation where the cutting
accessory may contact hidden wiring or its own
cord. Cutting accessory contacting a "live" wire may
make exposed metal parts of the power tool "live" and
could give the operator an electric shock�
Safety guidelines during power tool
operation
• Fix the workpiece. Use a fixing device or a vice to fix
the work piece for safely and steadily�
• Take necessary and proper safety measures when
harmful, flammable or explosive dust is produced in
the work� For example, dust that may cause cancer is
produced during the operation� Please use dust and
chip collecting device and wear a dust mask in the work�
• Keep workplace tide and clean� The mixed materials
would be extremely dangerous� Light metal dust would
be combusted and explode easily�
• Do not process materials that contain asbestos�
Asbestos is cancerogenic substance�
• Put down the power tool when the saw blade is fully
stopped�
• Do not use power tool when cable is damaged� If
the power wire is damaged or broken in the work, do
not touch it and pull out the plug immediately� Using
broken wire would lead to electric shock easily�
• Keep hands away from sawing area� Hand shall not
hold the lower part of work piece� Your hand would be
cut when it touches saw blade�
• First start the power tool and then put the power tool
of the workpiece to process it� If the saw blade is stuck
in the workpiece and power tool would rebound�
• Attention: the base plate shall cling to the workpiece
during the sawing. If the saw blade is deflected, it
would be broken and power tool would rebound�
• Cut off the power of power tool when work is done
and take the saw blade when the power tool is fully
stopped� The power tool wouldn't rebound in this way
and it can be put down safely�
• Use undamaged and crackles saw blade only�
Bended or dull saw blade would be broken easily and
cause rebound of power tool�
• After the power tool is shut down, do not stop the
moving saw blade by side pressure� The blade saw
would be damaged or broken and further lead to
rebound in this way�
• Use proper detector to detect whether there is
concealed circuit and pipeline in the operation area
and ask the local construction organization for
assistance if necessary� In the work, if the cable is
cut off, it would cause fire disaster and electric shock.
Damaged gas pipe would explode� If the water pipe
is cut off, it would cause property losses and electric
shock to the operator�
• Fix the saw blade rigidly with the saw holder� Check
the fixing of the saw blade regularly.
• Before cutting of wood, remove any metal objects
from the material (nails, screw nails, straps, etc�)�
• Avoid stopping an power tool motor when loaded�
• During operation watch the position of a power cable
(it should always be positioned behind the power tool)�
Do not allow it to whip around your legs or arms�
• Should power supply fail during work, immediately
turn the power tool's switch "Off" in order to avoid
accidental turning of the power tool on�
• After the power tool is switched off, the saw blade
keeps moving mechanically for some time, therefore
put the power tool aside only after the saw blade is
completely immobile�
• The saw blade gets quite hot during the operation,
therefore do not touch the saw blade until it is
completely cooled off�
Warning:
contained in dust generated in sanding,
cutting, sawing, grinding, drilling and
other construction industry activities may
result in cancer, congenital deficiency or be
harmful to the fertility. The ion of some chemical
substances shall be:
• before any repair and replacement work to
the machine, the power plug must be pulled out
firstly;
• the transparent two silicon oxide and other
masonry products in the wall bricks and cement;
the chromium arsenic (CCA) in wood with chemical
treatment� The harm degree of these substances
shall depend on the frequent degree of you carrying
out these works� If you want to reduce the contact
with these chemical substances, please work in
the place with ventilation and you shall use the
appliances with safety certificates (such as the dust
mask designed with tiny dust filter).

Symbols used in the manual

Following symbols are used in the operation manual,
please remember their meanings� Correct interpreta-
tion of the symbols will allow correct and safe use of
the power tool�
Symbol
English
19
the
chemical
substances
Meaning
Jigsaw
Sections marked gray - soft
grip (with insulated surface)�
Serial number sticker:
CT ��� - model;
XX - date of manufacture;
XXXXXXX - serial number�

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ct15189

Inhaltsverzeichnis