The display "V" lights information about work mode of
the water cooler (5"/on) for 2 seconds after the supply of
the wire feeder is switched on.
Changing Driving Rolls
The wire feeder is equipped with drive rolls for the wire
of 1.0 and 1.2mm (for LF 24/24 PRO) or 0.8 and 1.0mm
(for LF 22). For others wire sizes, is available the proper
drive rolls kit (see chapter Accessories for ordering the
desired kit). Below the drive rolls replacement
procedure:
Switch off the machine which supplies the wire
feeder.
Release the pressure roll lever [23].
Unscrew the fastening cap [24].
Open the protection cover [26].
Change the drive rolls [25] with the compatible ones
corresponding to the used wire.
For wires with the diameter greater than 1.6mm
(only for LF 24/24 PRO), the following parts are to
be changed:
The guide tube of the feeding console [27] and
[28].
The guide tube of the Euro socket [29].
Replace and tighten the protection cover [26] to the
drive rolls.
Screw the protection cover by fastening screws [24].
WARNING
WARNING
Maintenance
For any maintenance or repair operations it is
recommended to contact the nearest Technical Service
Center or Lincoln Electric.
performed by unauthorized service centers or personnel
will null and void the manufacturer's warranty.
The frequency of the maintenance operations may vary
in accordance with the working environment where the
machine is placed.
Any noticeable damage should be reported immediately.

Routine maintenance

Check condition of insulation and connections of the
work cables and input power supply cable.
Remove the spatters from the welding gun nozzle.
Spatters could interfere with the shielding gas flow
to the arc.
Check the welding gun condition: replace it, if
necessary.
Check condition and operation of the cooling fan.
Keep clean its airflow slots.

Periodic maintenance

Perform the routine maintenance and, in addition:
Keep the machine clean. Using a dry (and low
pressure) airflow, remove the dust from the external
case and from the cabinet inside.
Check condition of all connections and change if
necessary.
Check and tighten all screws.
Mains supply network must be disconnected from the
machine before each maintenance and service. After
each repair, perform proper tests to ensure safety.