Herunterladen Diese Seite drucken

Generating Compressed Air; Care And Maintenance; Periodic Maintenance; Machine Storage - Metabo BasicAir 350 Originalbetriebsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Use only extension cables with suffi-
cient lead cross section (see "Technical
Specifications").
Do not stop the compressor by unplug-
ging, but switch OFF using the switch.
Unplug after use.
5.4
Generating compressed
air
1. Switch on the machine (42 or 43).
Wait until the maximum tank pres-
sure is reached (the compressor
shuts OFF).
The tank pressure is indicated on the
tank pressure gauge (47).
BasicAir 250/350
42
43
PowerAir 350
46
44
42
45
2. Set pressure regulator (44) to re-
quired working pressure. The cur-
rent working pressure is indicated
on the regulated pressure gauge
(46).
A
Caution!
The regulated pressure may not be set
higher than the max. working pressure
of the connected air tools!
3. Connect air hose to compressed air
outlet (45).
4. Connect air tool. You are now ready
to work with the air tool.
5. Switch the compressor OFF, if you
do not continue working immediate-
ly afterwards. Unplug after switching
OFF.
48
6. Drain the condensate from the pres-
sure vessel once a day (48). To do
this, tilt the machine slightly.
6.

Care and Maintenance

44
A
45
Danger!
Prior to all servicing:
– Switch machine OFF.
– Unplug power cable.
46
– Wait until the compressor has come
47
to a complete stop.
– Ensure the compressor and all air
tools and accessories connected to
it are relieved from pressure.
– Let the device and all air tools and
47
accessories cool down.
After all servicing:
– Check to see that all safety devices
are operational.
– Make sure that no tools or other
parts remain on or in the machine.
Repair and maintenance work other
than described in this section must
only be carried out by qualified spe-
cialists.
6.1

Periodic maintenance

A
Caution!
On a new compressor pump, check the
tightening torque of the cylinder head
bolts (see 'Technical Data') after the
first 50 and 250 hours of operation.
ENGLISH
Prior to each use
Check air hoses for damage, re-
place if necessary.
Check all screwed connections for
tightness and tighten if necessary.
Check power supply cable for dam-
age and have replaced by a quali-
fied electrician if necessary.
Every 50 operating hours
Check air filter element (49) of com-
pressor pump, clean if necessary.
Check the oil level in the compressor
pump with the oil dip stick (50) and
refill oil if necessary.(51)
Every 250 operating hours
Replace air intake filter element of
compressor pump.
Every 500 operating hours
Drain oil and fill with fresh oil.
Every 1000 operating hours
Have unit serviced by an authorized
service station. This will extend the
compressor's service life considera-
bly.
6.2

Machine storage

1. Switch unit OFF and unplug.
2. Release pressure from tank and all
connected air tools.
3. Drain condensate from pressure
vessel .
49
50
51
13

Quicklinks ausblenden:

Werbung

loading

Diese Anleitung auch für:

Powerair 350Basicair 250