Herunterladen Diese Seite drucken

Balluff BSI R65K0-XB-MXS030-S115 Betriebsanleitung Seite 2

Mems neigungssensoren mit analogausgang bsi r65k0-x _-m _ _ _ _-s115-serie

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MEMS Inclination Sensors with Analog Output
BSI R65K0-X _-M _ _ _ _-S115
Inclination axes of the sensor with 2 measurement axes
The sensor's counting direction using two measurement
axes depends on its inclination alignment, for example:
For inclinations along the Y-axis:
Clockwise: from 0° to 45°, for example
Counterclockwise: from 0° to –45°, for example
For inclinations along the X-axis:
Clockwise: from 0° to 45°, for example
Counterclockwise: from 0° to –45°, for example
Y-axis
X-axis
Ordering
Types with 2 measurement
Measure-
code
axes
ment
angle
BSI0006
BSI R65K0-XB-MYS015-S115
±15°
BSI0007
BSI R65K0-XB-MYS030-S115
±30°
BSI0008
BSI R65K0-XB-MYS045-S115
±45°
BSI0009
BSI R65K0-XB-MYS090-S115
±90°
BSI000A
BSI R65K0-XA-MYS015-S115
±15°
BSI000C
BSI R65K0-XA-MYS030-S115
±30°
BSI000E
BSI R65K0-XA-MYS045-S115
±45°
BSI000F
BSI R65K0-XA-MYS090-S115
±90°
3
English
Output signal current 4 mA ... 20 mA
Output signal voltage 0 V ... 10 V
Maintenance
The device is maintenance-free in principle. The housing
can be cleaned as needed using a damp cloth and non-
corrosive cleaning solution when the device is switched off.
Decommissioning
Always uninstall the device in a deenergized state.
Disposal
The device must be disposed of according to European
Directives 2002/96/EC and 2003/108/EC (Waste Electrical
and Electronic Equipment). Equipment should be disposed
of separately from household waste!
MEMS Inclination Sensors with Analog Output
BSI R65K0-X _-M _ _ _ _-S115
Technical data
General data
Measuring range
±15°
depending on type
±30°
±45°
±90°
±180°
Measurement axes
Type BSI R65K0-..-MX...
1
Type BSI R65K0-..-MY...
2
Measuring principle
MEMS
Protection class
3
Electrical data
Supply voltage U
S
Type BSI R65K0-XB-...
10...30 V DC
Type BSI R65K0-XA-...
12...30 V DC
Rated operating voltage U
24 V DC
e
Output
Type BSI R65K0-XB-...
4...20 mA
Type BSI R65K0-XA-...
0...10 V
Load
Max. for current output
> 900 ohm
Min. for voltage output
> 20 k ohm
Resolution max.
0.01°
Stand-by delay
Max. 1.0 s
Polarity reversal protected
Yes
Short-circuit protected
Yes
Sampling rate
< 20 ms
Accuracy depending on type
±0.12° ... ±0.25°
(characteristic deviation)
Temperature drift
±0.1°/10 K
Current consumption
< 25 mA
Mechanical data
Housing material
Faradex DS
Dimensions LxWxH
60×50×27 mm
Weight
Approx. 110 g
Plug connector socket
M12x1, 8-pin
Ambient conditions
Operating temperature
–40...+85 °C
Storage temperature
–40...+85 °C
Relative humidity
95% non-condensing
Degree of protection
IP 67
as per IEC 60529
Enclosure Type as per UL 50/50E 1
www.balluff.com
UL requirements
This device is listed under UL Category Code Number
NRKH/NRKH7.
Intended for use with a Class 2 power source in accor-
dance with UL1310.
Use a UL-listed (CYJV/7) M12, 5-pin mating connector
with mechanical locking, wire thickness of at least 30
AWG (0.05 mm²), recommenced ≤ 23 AWG (≥0.34 mm²).
Balluff GmbH
Schurwaldstraße 9
73765 Neuhausen a.d.F.
Germany
Phone +49 7158 173-0
Fax +49 7158 5010
balluff@balluff.de
n
www.balluff.com
English
4

Werbung

loading

Diese Anleitung auch für:

Bsi r65k0-xb-mxs015-s115Bsi r65k0-xb-mxs090-s115Bsi r65k0-xb-mxs045-s115Bsi r65k0-xb-mxp360-s115Bsi r65k0-xa-mxs015-s115Bsi r65k0-xa-mxp360-s115 ... Alle anzeigen