5. Operation of the Heat Pump
5.1 Compressor Operating Sequence
There should be 3 minutes delay to restart compressor, after
Compressor stops operating (such as manual power off, constant
temperature Shutdown, ..)
5.2. Water Pump Operating Sequence
A. The compressor of heat pump should be started to run after
1 minute of water pump running .
B. Water pump should be closed after heat pump stopped
running about 1 minute.
5.3. Fan Motor Operating Sequence
A. When heat pump starts to run, fan should be run in 30 seconds before
compressor works.
B. When heat pump stops, fan should be stopped after 30 seconds of
compressor stopped.
6. Maintenance
6.1 Maintenance
(1) You should check the water supply system regularly to avoid the air
entering the system and occurrence of low water flow, because it would
reduce the performance and reliability of HP unit.
(2) Clean your pools and filtration system regularly to avoid the damage
of the unit as a result of the dirty of clogged filter.