an optimum level and there will be
an increase in noise.
Round pipes:
we recommend internal diameter: 150
mm.
Flat duct must have an internal cross
section that equates to that of round
pipes.
There should be no sharp bends.
Ø 150 mm ca. 177cm
If pipes have different diameters:
insert sealing strip.
For exhaust-air mode, ensure that
there is an adequate supply of fresh
air.
Connecting a Ø 150 mm exhaust air
pipe:
Mount the pipe directly onto the air
outlet on the hood. Duct smaller than
150 mm are not reliable.
With higher distance from the cooking
hob, the air delivery performances are
reduced. During the design and
layout of the mounting of the cooker
hood, kindly consider also the funnel-
shape of the vapour rising with
inclination of ca 10 – 15°.
Preparing the celing:
The ceiling must be flat and
horizontal.
Ensure that the ceiling is capable of
providing a firm hold for mounting screws
and plugs.
The enclosed plugs are suitable for
concrete and stonework. If the ceiling is
made of any other material, use
appropriate mounting components.
Attention: The cooker hood is
equipped with standard fixing material.
The person who is mounting the hood
should make sure that fixing elements are
suitable for the ceiling that is found. The
manufacturer declines any responsibility
for damages caused by a wrong mounting
2
oder use of unsuitable fixing elements for
the ceiling found.
For the weight kindly look at the M
Figures. We reserve the right to
construction changes within the context of
technical development.

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED.
The appliance must be installed so that
plug is accessible.
IMPORTANT: Fitting a different plug.
The wires in the mains leads are coloured
in accordance with the following codes:
Green and Yellow – Earth
Bleu – Neutral
Brown – Live
If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
This is what you have to do.
1.
Connect the green and yellow (Earth)
wire to the terminal in the plug market
"E " or with the symbol (
coloured green or green and yellow.
2.
Connect the bleu (Neutral) wire to the
terminal in the plug marked 'N' or
coloured black.
3.
Connect the brown (Live) wire to the
terminal marked "L" or coloured red.
The extractor hood should only be
connected to an earthed socket that has
been installed according to relevant
regulations.
If possible, site the earthed socket directly
above the chimney panelling in the ceiling.
Electrical Data: