OPERATION

Before use
• Upon First Operation, allow the unit to sit at room temperature for half of an hour
before running.
• It is recommended to operate the unit below a temperature of 20 °C and a relative
humidity of less than 80% RH.
• Use clear water not over 40 °C
• Check the water basin to make sure it is clear.
Operation
1. Put the unit on a flat surface.
2. Fill the water into the water tank, and then tighten the tank cover.
3. Put the water tank on the main base, and disable the child safety lock.
4. Check if the rated voltage is the same as the input voltage, and plug into the socket.
The symbol ON/OFF
5. Touch the symbol ON/OFF
background LED light will be on. The unit will begin to work in AUTO mode. Display
shows AUTO symbol, current temperature, current humidity and the vapor output
level symbol.
6. Touch the MODES
Night mode
• Display shows the night mode symbol l
humidity using the formula in auto mode and begins operating to achieve it at
maximum power.
• When the current humidity is less than the humidity shown in the table, high speed
operation. When the target humidity has been reached, the unit will switch to
minimum power.
Air temperature
≤19 °C
20 °C
21 °C
22 °C
23 °C
24 °C
25 °C
26 °C
will be lit.
on the unit. All function button will be backlit and the
,symbol to select night mode, health mode and auto mode.
. The device determines the optimal
Humidity
65 %
60 %
58 %
57 %
55 %
53 %
50 %
48 %