Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - NARVI SOFTY 6,8kW Installation Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SOFTY 6,8kW:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
The preset time has not run out yet, but you wish to switch on the sauna heater immediately.
1. Depress the SET button -> the yellow LED flashes, and the remaining power-on time
will be displayed.
2. Depress the + or - button as many times as is necessary to decrease the display reading to zero.
-> the heater is switched on and the On/Off LED in the top left corner glows red.
During the preset time it will not be illuminated at all.
3. Depress the SET button -> the green LED flashes.
4. Depress the SET button -> the red LED flashes.
5. Depress the SET button -> the heater remains switched on normally for the time
indicated by the display.

5. TECHNICAL SPECIFICATIONS

Technical specifications
• Temperature range
• Preset timing
• Power-on time
5.2 Upper card
• enclosure class
• the control unit can be
installed either in the sauna
or in the dressing room
5.3 Lower card
• voltage
• amperage
• heater capacity
• protection class
• overheating protection
• fuse
6. AIR EXCHANGE FOR THE STEAM ROOM:
-
The air exchange in the steam room must be as efficient as possible, in order to
guarantee sufficient oxygen content and availability of fresh air.
-
The fresh air is directed through a ca. 100-mm diameter duct preferably directly
from the outside to above the heater.
-
There must be a space of at least 1,000 mm between the temperature sensor and
the fresh air duct or 500 mm if the duct end can be turned.
-
The fresh air can also be directed close to the heater; to the side and underneath.
-
It is important to introduce fresh air, so that the air mixes with the air and the steam.
-
The exiting air should be exhausted as far as possible from the incoming air.
-
The air exhaust valve may be located under the sauna benches.
-
The exiting air may be directed out of the steam room through the washroom,
for instance under the door. There must be an approximately 100-150-wide slit
between the door and the floor.
60 ºC–115 ºC
max. 24 h
max. 4 h
IPX4
230 V 3N 50 Hz
16 A
max. 10.5 kW
IPX4
144 ºC
50 mA