Remedy of faults

Malfunction
Pump does not start.
Pump does not deliver.
Insufficient delivered quantity / unsatisfactory
fountain display
Pump switches off after a short running period.
Height of the fountain varies.

Maintenance and cleaning

A T T E N T I O N ! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Cleaning the unit
N O T E
Recommendation regarding cleaning:
• Clean the unit as required but at least twice a year.
• Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
How to proceed:
 J
1. Turn the filter basket counterclockwise and remove.
– The filter basket is fastened to the pump with a bayonet lock.
2. Clean all parts.
– Use a soft brush.
– Rinse parts in clean water.
3. Reassemble the unit in the reverse order.
N O T E
For soiled water, we recommend using a filter bag (available in specialist stores) to ensure that fewer dirt parti-
cles enter the unit. Place the filter bag around the pump filter basket and fasten correctly.
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Multifunctional nozzle clogged
Excessively soiled water
Water temperature too high
The impeller unit is blocked
Pump has run dry.
Dynamic Function activated
Remedy
Check the mains voltage.
Check supply lines.
Clean
Clean
Clean the multifunctional nozzle.
Clean the pump. The pump automatically
switches on again once the motor has cooled
down.
Note maximum water temperature of +35°C.
The pump automatically switches on again
once the motor has cooled down.
Disconnect the power supply and remove ob-
stacle. Then switch the pump on again.
Flood the pump. Fully submerge the pump for
operation in the pond.
Deactivate Dynamic Function