Herunterladen Inhalt Inhalt Diese Seite drucken

Quick BX 15 Benutzerhandbuch Seite 15

Vorschau ausblenden Andere Handbücher für BX 15:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
POS. DESCRIPTION
2
Red plastic washer
3
White plastic washer
4
Blue plastic washer
5
Relief/non return valve
6
Hose clamp
7
Discharge pipe
8 A
Element gasket
from S/N 100.000
8 B
Element gasket
from S/N 200.000
9A
Electric element
1200W 220V
9B
Electric element
500W 220V
9C
Electric element
1200W 110V
9D
Electric element
600W 110V
10
Bi-Thermostat
11
Power supply cable
12A
Boiler resistor cover 220V
12B
Boiler resistor cover 110V
13
Nut
14
Ground cable terminal
15
Washer
16
Screw 2,9 x 19
17A
Tank mounting
BX15-BX20-BX25
17B
Tank mounting
BX26-BX30-BX40
17C
Tank mounting
BX41-BX50-BX60-BX80
18
Bolt
19
Washer
20
Nut
21
Cable clamp
22
Screw 2,9 x 16
BOILER BX15-100 - REV006A
CODE
PECRBLRS0000
PECRBLBNC000
PECRBLBL0000
MNVALS12S68P
• shut down power supply.
PBF25100W000
• Remove the protection cover (12) in order to reach
PVTBGM10NT00
the thermostat (10).
• Push the reset button on the double thermostat (fi g. 4).
PGGRES000000
• Replace on the protection cover (12).
• Switch on power supply.
PGRM43500000
EVR12220N000
EVR05220N000
MAINTENANCE
EVR12110N000
We recommend checking the magnesium anode (A) every
EVR06110N000
12 months.
EVT15S000000
Replace the anode if its size has been reduced signifi cantly.
ECC30150G000
This simple and preventive maintenance will ensure a long
PECRB2200000
life of the equipment.
PECRB1100000
MBD04MXEN000
EJCY04000000
F
MBR04X000000
MBV02919AXCC
MMSTBL300DR1
The overpressure release device must be activated regu-
larly to remove calcium deposits and to ensure that it is not
MMSTBL400DR1
blocked.
MMSTBL400DR1
Periodically check the joints of the water pipe installation;
MBV0830MXE00
check the tightness of the securing screws and replace
MBR08X000000
them in case they are worn or corroded.
MBD08MXEN000
PPBLBX000000
Also periodically check the electrical system working order.
MBV02916AXCC
MAINTENANCE
WARNING: Quick
®
nautic water heaters are provided
with a double thermostat with manual reset that
shuts down power supply in case of an excessive
water temperature.
If it happens, follow the instructions below:
WARNING: if the high temperature safety system
switches on repeatedly, call Quick
During wintertime, when the water heater is not
in use it should be drained using the lever of the
valve (5). This is to avoid serious damage caused by
freezing.
GB
®
service center.
15