Z6AM
NOTE
The following tightening moments prescribed for the fastening bolts
must be adhered to when replacing the load cell:
up to 200 kg max. capacity
500 kg max. capacity
The setting of the overload stop must be checked after the replacement
load cell has been installed. Please refer to the specifications for the
weighing module: "Play on overload stop".
4

Operation

− Dust, dirt and other foreign bodies must not be allowed to collect in such a
way that movement of the transducer (bellows) is restricted.
− The gap for the overload stop and lateral stops must also be kept free of
contamination.
− The play of the overload stop (for details see table "Specifications for the
weighing module") should be checked at regular intervals, for instance with
a feeler gage, and be readjusted if necessary.
− The weighing modules should not be completely relieved of load. This pre-
vents the load application elements from lifting out.
− Lateral displacements which exceed the maximum permissible value and
do not act in the direction of the stay rods should be avoided by aligning the
other modules appropriately, or should be absorbed by other stops or reten-
tion devices.
− The play in the stay rods should be regularly checked and if necessary re-
adjusted.
A1559-2.0 de/en/fr
Galvanized version:
Stainless steel version:
Galvanized version:
Stainless steel version:
21
34 N@m
23 N@m
76 N@m
45 N@m