1. Safety Guidelines

1. Follow the installation instructions.
2. Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3. Note that the appliance is exclusively for use in the appli-
cations detailed in these installation instructions. Any
other use will not be considered to comply with require-
ments and would invalidate the warranty.
4. Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried out by
authorized persons.
5. Immediately rectify any malfunctions which may influence
safety.
Only a gentle turning is needed to close the valve.
Tightening with too much force does not improve
the sealing, but can rather cause a malfunction.
The water in the pipe must drain out.
Remove hoses and screw connections before the
frost period.

2. Description of function

The frost-protected Alwa-Outside Tap is used as external
shut-off valve for potable water installations, for example as
outside tap. The tap is on the outside and the valve is on the
frost-protected inside of the wall. It's a self-draining tap.

3. Technical data

Medium
Water
Range of Application -30 °C ... 60 °C
Operating pressure
max. 10 bar (PN 10)
k
-value
2.1 m
vs

4. Scope of delivery

The Outside Tap consists of:
• Valve body with external threads to DIN ISO 228/1 to be
installed inside
• Valve insert for wall thickness
up to 450 mm V4720X0015 and
up to 580mm V4720X0015L
• Fitting with check valve and vacuum breaker according to
DIN 1988, part 4 and DIN EN 1717, type HD
• Compression connection
• Stop plate
• Hose connector
Honeywell GmbH
/h
3
GB

5. Assembly

5.1. Wall bushing and outside connection
1. Drill bore hole at least Ø 28 with gradient to outside (at
least 2°) through wall
2. Guide copper pipe (22 mm) from inside through the wall.
3. Put the stop plate, gland nut (not chrome-plated) and
clamping ring onto the pipe.
4. Pull valve housing (size 20) on all the way and screw with
gland nut (size 32).
Screw the gland nut with a torque of 30
wise there exists the danger of jamming of the inner
parts.
5. Push unit towards pre-fab wall.
5.2. Cut copper pipe to length
1. Cut copper pipe (22mm) to length outside to 51 mm
distance to the pre-fab wall and deburr.
2. Put the clamp ring screw connection, consisting of a
rosette pressure disc, clamp screw connection and clamp
ring, onto the copper pipe.
3. Put the rosette onto the drain tap.
4. Pull drain housing (size 27) on all the way and screw with
clamp screw connection (size 32).
Screw the gland nut with a torque of 30
wise there exists the danger of jamming of the inner
parts.
5. Screw the rosette with inserted pressure disc against the
pre-fab wall.
6. Loosen spindle housing (size 22)
7. Shorten valve insert the same amount as the copper pipe
(22mm)
8. Insert valve insert to borehole in the spindle; push in all
the way.
9. Insert mounted valve insert with spindle housing (SW22)
in the pipe and screw tight.
10. Put on snap-in bushing and handle.
11. Attach hose coupling.
5.3. Inside connection
1. Connect tap to piping with a clamp ring screw connection
or 1/2" thread.
4
Nm, other-
+10
Nm, other-
+10
MU1H-1815GE23 R0212