3
press AP/CH button or the remote control: both leaves will open;
4
once opening is complete, press AP/CH button or the remote control: both leaves will stop;
5
press AP/CH button or the remote control: the leaf #2 will close at standard speed;
6
when the leaf is completely closed press AP/CH button or the remote control (leaf #2 program-
ming completed);
7
press AP/CH button or the remote control: the leaf #1 will close at standard speed;
8
when the leaf is completely closed press AP/CH button or the remote control (leaf #1 program-
ming completed);
9
the DL7 LED will stop blinking and remain steady ON (programming completed and saved).
GATE 1 WINGS - DIP SWITCH # 4 in OFF (Soft-Stop function disabled):
1
press and hold down for at least 5 seconds P1 and P2 buttons to activate the programming
mode;
2
the DL7 LED will begin blinking fast to confirm that programming mode is active;
3
press AP/CH button or the remote control: the leaf will open;
4
once opening is complete, press AP/CH button or the remote control: the leaf will stop;
5
press 3 times AP/CH button or the remote control: the leaf will close at standard speed;
6
when the leaf is completely closed press AP/CH button or the remote control (leaf programming
completed);
7
the DL7 LED will stop blinking and remain steady ON (programming completed and saved).
Notice:
-
during the SETUP procedure the safety devices are disabled.
-
STOP input will stop the programming at any time. The programming mode remains active
and can be re-started from point 1
-
while DL7 blinks, press and hold down for at least 5 seconds P1 and P2 buttons to kill exit
programming mode
-
set a working time slightly longer than necessary (a couple of seconds) to allow complete
opening/closing of the leaves.
DIP SWITCH
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
3
NO REVERSE
4
DECELERATION
5
PRE-FLASHING
6
FOTOTEST
18
after opening, the gate automatically closes when the delay set on
On
the T.C.A. trimmer expires;
Off
automatic closing disabled;
with automatic closing enabled, a sequence of open/close com-
On
mands causes the gate to OPENCLOSE-OPEN-CLOSE etc (see
also dip switch 3);
in the same conditions, the same command sequence causes the
Off
gate to OPEN-STOP-CLOSE-STOP-OPEN-STOP (step-by-step);
the gate ignores the close command while it is opening (NO RE-
On
VERSE);
Off
the gate behaves according to the position of dip-switch n° 2;
the deceleration function is on (see "PROGRAMMING INSTRUC-
On
TIONS");
Off
the deceleration function is off;
On
the pre-flashing function enabled;
Off
the pre-flashing function disabled;
On
the "photocell test" function is enabled;
the "photocell test" function is disabled. N.B.: to be used when the
Off
photocells are not used;