Programming

All parameters may be displayed at any time. For modi-
fications the jumper on the backside of the device must be
removed (not on position LOCK).
The following table shows all parameters with their adjus-
table ranges or possible selections respectively. The black
numbers give a cross-reference to the appropriate diagram
position on page 30.
Starting at the measurands display by pressing the key
you may change to the menu level.
Afterwards you can select the desired menu item by pressing
the key
shortly.
P
Use
to enter the level where the desired parameter is
displayed.
Pressing
shortly will force the selectable element to flash.
P
The flashing content may be modified using the keys
.
Press
for a longer time to leave the parameter or menu
P
level.
All settings will remain non-volatile stored even in case of
power-fail.
Hints:
First you have to set the system configuration and the
transformer ratios because further measurand selections,
alarm limit settings etc. will depend on them.
The programming may be modified via an optional interface
module as well.

Parameters overview

No.
Topmost display
Middle display
1
2
3
4
5
24
Mod-Tronic Instruments Limited Tel: 1 800 794-5883 Fax: 1 800 830-7122 www.mod-tronic.com
Undermost display
Meaning
(Selection,
* = default)
System configuration
*
4-line system, unbalanced load
3-line system, unbalanced load
4-line system, balanced load
3-line system, balanced load
Single-line system
*
Primary voltage of an external transformer
on the voltage input (line-to-line voltage)
100 V to 999 kV
*
Secondary voltage of an external
transformer on the voltage input
100 V bis 999 V
(line-to-line voltage)
*
Primary current of an external transformer
on the current input
1.00 A to 999 kA
*
Secondary current of an external
transformer on the current input
1.00 A to 9.99 A
Locking the configuration
Place the jumper in the LOCK position.
The configuration of all parameters is disabled.

Factory Default

P
Brightness:
Limit value / S01:
Limit value / S02:
Transformer ratio: 1 : 1
Jumper:
Connecting mode: 4 wire asymmetric load
Synchronizing
interval:
or
LOCK
(mid setting)
Off
Off
Not in the LOCK position
15 min.
Hints
(4 lines unbalanced)
(3 lines unbalanced)
(4 lines balanced)
(3 lines balanced)
(1 line)
First you enter any 3-digit number followed
by the appropriate power unit selection in
steps of factor 10