Display and operating

Available measurement data

Phase voltages U1, U2, U3
Maximum value U1
, U2
max.
max.
Minimum value U1
, U2
min.
min.
Delta voltages U12, U23, U31
Maximum values U12
, U23
max.
Minimum values U12
, U23
min.
Phase current I1, I2, I3
Maximum values I1
, I2
max.
max.
Average values I1
, I2
, I3
avg
avg
Max. average values I1
avgmax.
Neutral current IN
Active powers P1, P2, P3
Maximum values P1
, P2
max.
Active power system P
Maximum value P
max.
Reactive power Q1, Q2, Q3
Maximum values Q1
, Q2
max.
Reactive power system Q
Maximum value Q
max.
Apparent power S1, S2, S3
Maximum values S1
, S2
max.
Apparent power system S
Maximum value S
max.
Power factor PF1, cosϕ
Power factor PF2, cosϕ
Power factor PF3, cosϕ
Power factor system PF, cosϕ
Minimum value power factor inductive
Minimum value power factor capacitive
Frequency, F
Active energy incoming EP high tariff
Active energy incoming EP low tariff *)
Active energy outgoing EP high tariff
Active energy outgoing EP low tariff *)
Reactive energy inductive EQ high tariff
Reactive energy inductive EQ low tariff *)
Reactive energy capacitive EQ high tariff
Reactive energy capacitive EQ low tariff *)
5 intervals active power Pint0, Pint1, ...
5 intervals reactive power Qint0, Qint1, ...
5 intervals apparent power Sint0, Sint1, ...
*) Tariff switching via digital input only (optional interface module required)
Determination of measured quantities
The calculation of the measurements is made in accordance with EN 40 110, with the exception of the reactive power. This is calculated by the
SINEAX A 210 as a signed value.
Transducers and displays can possibly display different values for the reactive power in the same power system.
The reason is the different calculation methods.
22
Mod-Tronic Instruments Limited Tel: 1 800 794-5883 Fax: 1 800 830-7122 www.mod-tronic.com
top
7-segment
centre
display
bottom
Key for
P
programming
and display
Example
display
top
230
, U3
235
max.
, U3
227
min.
400
, U31
405
max.
max.
, U31
395
min.
min.
2.35
, I3
2.39
max.
2.04
avg
,I2
,I3
2.07
avgmax.
avgmax.
56.1
, P3
60.5
max.
max.
1.24
, Q3
1.51
max.
max.
2.56
, S3
3.43
max.
max.
4589
1234
4589
1234
9876
1234
9876
1234
Example
Example
Units
display
display
display
centre
bottom
231
229
V
236
231
V
226
225
V
402
398
V
406
403
V
397
396
V
2.37
2.34
A
2.40
2.38
A
2.05
2.07
A
2.05
2.04
A
0.45
A
56.2
56.5
kW
60.4
60.3
kW
125
kW
239
kW
1.23
1.22
VAr
1.52
1.54
VAr
1.54
VAr
2.31
VAr
2.58
2.60
VA
3.44
3.67
VA
5.33
VA
6.23
VA
ϕ
0.87
ϕ
0.88
ϕ
0.89
ϕ
0.88
ϕ
0.76
ϕ
0.84
49.99
Hz
2356
kWh
5678
kWh
2356
kWh
5678
kWh
5432
kVarh
9876
kVarh
5432
kVarh
9876
kVarh
234
kW
123
VAr
10.1
VA
Units display
System display
Power factor
Up key
cosϕ 4 quadrant
operation
Down key
System
display
P
System
P
Phase 1
P
Phase 2
P
Phase 3