Herunterladen Inhalt Inhalt Diese Seite drucken

Chauvin Arnoux CDA 103 Bedienungsanleitung Seite 15

Multitester
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Auto OFF
Once it is disconnected from the circuit, the
multitester switches OFF automatically; the
display goes blank.
Live/neutral identification
Because of its great sensitivity, the multitester
detects live and neutral in a power point.
- Socket without earth. Insert the positive prod
(red) into the socket ; with the black prod in
the air. If the display lights it is live. If the
display remains unlit, it is the neutral.
- Socket with earth. By connecting the black
prod to the earth, and the other one to the
live or the neutral, the earth/live or earth/
neutral voltage is measured, without setting
off RCD's (consumption 1.4 mA at 380 V).
SPECIAL FUNCTIONS ON THE CDA 104
Hold: see Description (HOLD)
Backlighting of the display :
see Description (
Additional 200mV DC range (Z = 1 MW )
It is possible to temporarily go below the mini-
mum voltage threshold of 600mV on DC. With
the CDA 104 disconnected from all circuits,
proceed as follows.
Press simultaneously the HOLD button and
the ohmmeter button ; the multitester sets to
DC voltage for approx 20 seconds :
- 200 mV DC range (0 to 199.9 mV)
- 2 V DC range (0.200 V to 1.999 V)
V DC and AC
Resolution
Impedance
Accuracy
Permissible
overload
(1) Operating range : 10 Hz to 400 Hz sine.
(2) Display 2000 counts limited to 600V rms.
(3) Accuracy as a % of the reading.
2 V
(1)
1 mV
600 kW
(3)
).
20 V
10 mV 100 mV
± 2 % ± 2 cts on DC and
± 3 % ± 5 cts on AC
1000 V rms for 5 seconds
15
200 V 600 V
260 kW
(2)
1 V

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cda 104

Inhaltsverzeichnis