SENSOR SWITCHING
By pressing the L/S key once, a -sign is indicated on the display. Wait un l the
-sign is shown. During the -sign indica on, the key has to be pressed again.
Now the previous selected sensor top (
) or bo om (
indicated. If during this display, this bu on is pressed again, the device toggels
to the other sensor.
Upper Sensor Indica on
Lower Sensor Indica on

INSTALLING BATTERY

Open the ba ery lid on the backside of the meter.
Install a 9 volt L6R22.
Close the lid.
A low voltage is indicated with
to the le ; upper side on the display
when the ba ery needs to be replaced. A new ba ery should be inserted to
achieve correct measuring results.

ENVIRONMENT PROTECTION

According to the regula ons for ba ery dispose, all
ba eries must be returned to the trade or to ba ery
collec ng points. You are not allowed to dispose ba eries
through the household waste.
ONLY FOR EU COUNTRIES
Do not dispose of electrical tools together with household
waste material! In observance of European Direc ve
2002/96/ EC on waste electrical and electronic equipment
and its implementa on in accordance with na onal law,
electric tools that have reach the end of their life must be
collected separately and returned to an environmentally
recycling facility.
SELECTION OF WOOD GROUPS OR BUILDING
MATERIAL GROUPS
A er the unit has been switched on, the previous selected
sensor (top sensor with
or bo om sensor with
followed by the wood density 200-1180 kg/m3,
or building material CC2-b30 is indicated on the Display.
If this key is kept pressed, the group increases by itself
automa cally while increasing the velocity, as longer it is kept pressed. Or a er
releasing and pressing the key E repe
vely, the wood group will increase by
20kg/m³ or the next Material group is selected. A er 2 sec. the unit is ready
to take measurements. The indicated wood group is equivalent to the density
of the mber.