Pinless Moisture Meters
MC-380XCA
Manual
INTRODUCTION
With the MC-380XCA moisture-measuring instrument,
EXOTEK INSTRUMENTS has introduced a hand-held moisture-measuring unit,
incorpora ng electronic circuitry perfected over years of development and
prac cal applica ons with the latest technology.
It is easy to determine moisture content in wood and building materials
with the contact measurement procedure without destroying the material.
Reliability, durability and a high standard of accuracy are assured by
modern, digital and analogue components built to cope with the stress
of everyday use.
The se ng of wood-groups and building material groups combined with
an automa c zero-correc on, allow more accurate measurements on all
European as well as Tropical mbers, as well as on a great number of
building materials.
The Unique switchable dual Scanning Depth of 10 and 100 mm
makes it easy to determine Moisture Content even in fl oors with
built in Central Hea ng.
SWITCH-ON
By pressing this key once, if the device is off , the unit is
switched on.
SWITCH-OFF
By pressing this key once, if the device is on, the unit is
switched off .
Or: Automa cally a er approx. 30 seconds if the value does not change.
ALARM FUNCTION
The MC-380XCA has the possibility to give an acous c
alarm in case of an user selectable alarm threshold is
reached or exceeded. This func on is most useful for
sor ng out mbers.
By pressing this key once, a -sign is indicated on the display. During this indica-
on, the key has to be pressed again. Now the actual threshold value (L6 – L30
or; L 0.6-L 3.0 or; 60-99% in RH mode) if the Building material group CC2 – b30
is selected) is indicated and the alarm func on is ac vated. In case this key is
pressed again, while the limit is indicated, the threshold value is being increa-
sed by 1% moisture in the range of 6 – 30% or If the CC2 to B30 is selected the
alarm threshold is increased with 0,1%. For RH mode the step increases by 1%
when the key is pressed). A er 2 sec. the unit is ready to take measurements.
To turn off the alarm func on, select only a diff erent func on.
ENG
- 4 -