Commissioning
Surface Mount Variant
DDZ4010-SM/HS/HD
DDZ4 1 10-SM/HS/HD
DK 150.700 / Rev. 1.0.0 / 2010-03-22
BackPlate with
built-in plug-in module
Locked and secured
PTZ Dome
Securing screw (Housing ring):
Hexagon socket set screw
Thread for securing screw
with cone point DIN 914 M2.5×4
(Housing ring)
Fig. 4
11
7
3
9
5
1
10
6
2
Weidmüller male connector
12
8
4
SL 3.50/02/90G
Fig. 5 Terminal area
Pin No.
Assignment
Pin No.
Assignment
1
Rx+
2
Rx−
3
Tx+
4
Tx−
5
GP Out
6
GND I/O
7
GP In 1
8
GND I/O
9
GP In 2
10
GND I/O
11
GP In 3
12
GND I/O
© 2010 Dallmeier electronic
All rights reserved.
We reserve the right to make technical modifications.
All trademarks identified by ® are registered trademarks of Dallmeier electronic.
English
All trademarks identified by *) are trademarks or registered trademarks of the following owners:
Adobe and Flash of Adobe Systems Incorporated headquartered in San José, California, USA
IBM of International Business Machines Corporation headquartered in Armonk, New York, USA
Microsoft, ActiveX, DirectX, Internet Explorer, Windows and Windows Vista of Microsoft Corporation
headquartered in Redmond, Washington, USA
Dallmeier electronic GmbH & Co.KG
Cranachweg 1, 93051 Regensburg, Germany
www.dallmeier.com / info@dallmeier.com
Safety Instructions
Only use this unit if it is technically in proper working order, to the intended pur-
pose and while keeping safety and potential dangers in mind!
Read and pay attention to the documents!
Observe the rated voltage! Observe ratings!
WARNING
Device falling off or collapsing ceiling
Danger of death or serious injury to the head
¾ Observe the manufacturer's instructions about the maximum
adequate carrying capacity of the supporting structure.
¾ Use screws suitable for the ceiling material.
¾ Use the correct type of anchor for your ceiling type:
• Plastic screw anchors for solid wall material (concrete/brick)
• Toggle bolt style anchors for drywall / hollow wall type (plaster)
Electric shock hazard
Danger of death or serious injury
¾ Disconnect the power supply unit from the mains socket before
connecting the device.
Appropriate Use
The DDZ4010-SM/HS/HD (DDZ4110-SM/HS/HD) is a High Definition
PTZ dome camera. It is designed for indoor installations on ceilings and can be
operated via PoE (Power over Ethernet, Class 4) or at 24 V AC.
Installation and Commissioning
The BackPlate is mounted with 3 screws (4×60 mm) to the ceiling.
¾ Loosen the securing screw of the housing ring (Fig. 4).
¾ Unscrew the housing ring (counter-clockwise).
¾ Loosen both securing screws of the PTZ dome camera (Fig. 1).
¾ Remove the PTZ dome camera (pull without using force).
¾ Loosen both securing screws of the plug-in module (Fig. 3).
¾ Remove the plug-in module (pull without using force).
¾ Mark the drill holes on the ceiling. Use the delivered drill template.
¾ At the marked locations, drill holes fitting for the screws/anchors to be used.
¾ Push anchors suitable for the ceiling material in the drill holes.
¾ Run the required cables through the cable entry of the BackPlate.
¾ Connect the required cables to the connectors of the terminal area (Fig. 5) in
the BackPlate.
¾ Mount the BackPlate with 3 screws to the ceiling.
¾ Insert the plug-in module carefully into the BackPlate until it clicks into place.
Pay attention to the correct alignment of the plug-in module (see Fig. 3).
¾ Tighten both securing screws of the plug-in module.
¾ Insert the PTZ dome camera into the BackPlate until it clicks into place.
Pay attention to the correct alignment of the connectors.
¾ Tighten both securing screws of the PTZ dome camera.
¾ Screw the housing ring onto the BackPlate.
¾ Tighten the securing screw of the housing ring.
¾ Connect the power supply unit to the mains socket.
Views and Connection Assignment
Drill hole
Ø 6 mm
Ceiling
Anchor
BackPlate
Cable entry
Locking clip
(PTZ Dome)
Locking clip
Mounting screw 4×60 mm
(PTZ Dome)
(BackPlate)
Securing screw
(Plug-in module)
Securing screw
(Plug-in module)
Plug-in module
Slot for locking clip
(BackPlate)
PTZ Dome
Securing screw
Securing screw
(PTZ Dome)
(PTZ Dome)
Housing ring
with bubble
Fig. 1
Connection
The configuration of the device is carried out with a PC/web browser via the local
area network (LAN).
Alternatively, the PC can be directly connected to the device via an Ethernet
crossover cable.
The factory default IP address of the device is 192.168.2.28.
Minimum System Requirements
Computer
IBM
-PC compatible
*)
Processor (CPU)
1.3 GHz
Random Access Memory (RAM)
256 MB
Operating System
Microsoft
*)
Windows
*)
2000
Microsoft Windows XP
Windows Vista
*)
each with latest service pack
Web Browser
Microsoft Internet Explorer
, latest version
*)
Graphics Card
DirectX
9.0 compatible
*)
Ethernet
100 Mbps
Software
Adobe
*)
Flash
*)
Player, latest version
Dallmeier control for ActiveX
*)
, latest version
¾ Ensure that the PC/web browser can establish a connection to the device via
Ethernet.
¾ Start the web browser.
¾ Enter the IP address of the device into the address bar of the web browser.
¾ Confirm the input.
The connection to the device is established.
The graphical user interface (GUI) of the live mode is displayed.
Login
The factory default password of user group Group 1: admin is "3".
¾ Click CONFIG in the user interface of the live mode.
¾ Enter the Username if required.
¾ Enter the Password.
¾ Confirm with OK.
The graphical user interface of the configuration mode is displayed.
¾ Configure the required settings and finally click LOGOUT.
Thread for securing screw
(PTZ Dome)
Terminal area
Mounting hole for
Thread for securing screw
4×60 mm screw
(Plug-in module)
Locking clip
Locking clip
(PTZ Dome)
(PTZ Dome)
Mounting hole for
Mounting hole for
4×60 mm screw
4×60 mm screw
Cable entry
Thread for securing screw
(Plug-in module)
Thread for securing screw
(PTZ Dome)
Fig. 2 BackPlate (top view without plug-in module)
Thread for securing screw
(PTZ Dome)
USB / SDHC port
Securing screw
(Plug-in module)
Locking clip
Locking clip
(PTZ Dome)
(PTZ Dome)
Securing screw
(Plug-in module)
Thread for securing screw
(PTZ Dome)
Fig. 3 BackPlate (top view with built-in plug-in module)
Technical Data
Following technical data was valid at the time of document compilation.
Refer to www.dallmeier.com for possible updates.
Audio IN
1× 3.5 mm phone jack (Line-In, stereo)
Audio OUT
1× 3.5 mm phone jack (Line-Out, stereo)
Ethernet
1× RJ45, 10BASE-T-/100BASE-TX-PoE
Local Video Memory
Via integrated USB / SDHC port
(adapter for SDHC card separately available)
Contact IN / Relay OUT
3× IN / 1× OUT
Serial
1× RS485 (full-duplex)
Voltage Supply
24 V AC ±10% (50 / 60 Hz) or via PoE (Class 4)
PoE Conformity
IEEE 802.3af (no PoE adapter required)
Power Consumption
Max. 25 W
Dimensions
Approx. Ø 155 × H 206 mm
Weight
Approx. 1755 g
Operating Temperature
−10 °C to +40 °C
Humidity
0 % – 90 % RH non-condensing

Werbung

loading

Inhaltszusammenfassung für dallmeier Domera DDZ4011-SM

  • Seite 1 All rights reserved. (PTZ Dome) We reserve the right to make technical modifications. Terminal area All trademarks identified by ® are registered trademarks of Dallmeier electronic. Mounting hole for English Thread for securing screw All trademarks identified by *) are trademarks or registered trademarks of the following owners: 4×60 mm screw...
  • Seite 2 Gewinde für Sicherungsschraube Alle Rechte vorbehalten. (PTZ-Dome) Technische Änderungen vorbehalten. Anschlussfeld Mit ® gekennzeichnete Marken sind eingetragene Marken von Dallmeier electronic. Befestigungsloch für Deutsch Mit *) gekennzeichnete Marken sind Marken oder eingetragene Marken folgender Eigentümer: 4×60 mm Schraube Gewinde für Adobe und Flash von Adobe Systems Incorporated mit Hauptsitz in San José, Kalifornien, USA...

Diese Anleitung auch für:

Domera ddz4011-hsDomera ddz4010-smDomera ddz4010-hsDomera ddz4010-hdDomera ddz4011-hd