Herunterladen Diese Seite drucken

dallmeier DOMERA DDZ30XX-SM/IP Inbetriebnahme

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Commissioning
Surface Mount Variant
DDZ30XX-SM/IP
DK 126.800 / Rev. 1.0.0 / 2010-07-15
Lens protection cap
Adhesive tape
M3 securing screw
Slot for locking clip
Fig. 4 PTZ dome camera
© 2010 Dallmeier electronic
All rights reserved.
We reserve the right to make technical modifications.
All trademarks identified by ® are registered trademarks of Dallmeier electronic.
English
All trademarks identified by *) are trademarks or registered trademarks of the following owners:
Adobe and Flash of Adobe Systems Incorporated headquartered in San José, California, USA
IBM of International Business Machines Corporation headquartered in Armonk, New York, USA
Microsoft, ActiveX, DirectX, Internet Explorer, Windows and Windows Vista of Microsoft Corporation
headquartered in Redmond, Washington, USA
Dallmeier electronic GmbH & Co.KG
Cranachweg 1, 93051 Regensburg, Germany
www.dallmeier.com / info@dallmeier.com
Safety Instructions
Only use this unit if it is technically in proper working order, to the intended pur-
pose and while keeping safety and potential dangers in mind!
Read and pay attention to the documents!
Observe the rated voltage! Observe ratings!
WArnIng
Device falling off or collapsing ceiling
Danger of death or serious injury to the head
¾ Observe the manufacturer's instructions about the maximum
adequate carrying capacity of the supporting structure.
¾ Use screws suitable for the ceiling material.
¾ Use the correct type of anchor for your ceiling type:
• Plastic screw anchors for solid wall material (concrete/brick)
• Toggle bolt style anchors for drywall / hollow wall type (plaster)
Electric shock hazard
Danger of death or serious injury
¾ Disconnect the power supply unit from the mains socket before
connecting the device.
Appropriate Use
The BackPlate DDZ30SM-IP is designed for indoor surface mount applications
and provides the IP based operation of the PTZ dome cameras
DDZ3018-SM/RP, DDZ3018-SM/HS, DDZ3026-SM/HS and DDZ3036-SM/HS.
Installation and Commissioning
Tools required for installation include:
• Marking tool (e.g. awl)
• 3 mounting screws (Ø 4 mm)
• 3 anchors
• Electric drill
• Screwdriver
• Hexagon socket screw key (wrench size 1.3)
The BackPlate is mounted with 3 screws (4×60 mm) to the ceiling.
¾ Loosen the securing screw of the housing ring.
¾ Unscrew the housing ring (counter-clockwise).
¾ Mark the drill holes on the ceiling. Use the delivered drill template.
¾ At the marked locations, drill holes fitting for the screws/anchors to be used.
¾ Push anchors suitable for the ceiling material in the drill holes.
¾ Run the required cables through the cable entry of the BackPlate.
¾ Connect the required cables to the connectors of the IP board.
¾ Mount the BackPlate with 3 screws to the ceiling.
nOTICE
Ensure the correct settings of the Rotary/DIP switches before installing the PTZ
dome camera. For detailed information refer to the separate documentations.
¾ Before installing the PTZ dome camera, remove the adhesive tape and the lens
protection cap.
¾ Insert the PTZ dome camera into the BackPlate until it clicks into place.
Pay attention to the correct alignment of the connectors.
¾ Tighten both M3 securing screws of the PTZ dome camera.
¾ Screw the housing ring onto the BackPlate (clockwise).
¾ Tighten the securing screw of the housing ring.
¾ Connect the power supply unit to the mains socket.
The device starts booting and is ready for operation after a short self-test.
Views and Connection Assignment
Drill hole
Ø 6 mm
Ceiling
Cable entry
Anchor
BackPlate with thread
for housing ring
Locking clip
Thread for
Thread for
M3 securing screw
M3 securing screw
Locking clip
IP board
Mounting screw
4×60 mm
Slot for locking clip
M3 securing screw
PTZ dome
M3 securing screw
Housing ring
with bubble
Securing screw (Housing ring):
Hexagon socket set screw
with cone point DIN 914 M2.5×4
Fig. 1 Installation
Connection
The configuration of the device is carried out with a PC/web browser via the local
area network (LAN).
Alternatively, the PC can be directly connected to the device via an Ethernet
crossover cable.
The factory default IP address of the device is 192.168.2.28.
Minimum System requirements
Computer
IBM
-PC compatible
*)
Processor (CPU)
1.3 GHz
Random Access Memory (RAM)
256 MB
Operating System
Microsoft
*)
Windows
*)
2000
Microsoft Windows XP
Windows Vista
*)
each with latest service pack
Web Browser
Microsoft Internet Explorer
, latest version
*)
Graphics Card
DirectX
9.0 compatible
*)
Ethernet
100 Mbps
Software
Adobe
*)
Flash
*)
Player, latest version
Dallmeier control for ActiveX
*)
, latest version
¾ Ensure that the PC/web browser can establish a connection to the device via
Ethernet.
¾ Start the web browser.
¾ Enter the IP address of the device into the address bar of the web browser.
¾ Confirm the input.
The connection to the device is established.
The graphical user interface (GUI) of the live mode is displayed.
Login
The factory default password of user group Group 1: admin is "3".
¾ Click CONFIG in the user interface of the live mode.
¾ Enter the Username if required.
¾ Enter the Password.
¾ Confirm with OK.
The graphical user interface of the configuration mode is displayed.
¾ Configure the required settings and finally click LOGOUT.
Thread for M3
securing screw
Mounting hole for
4×60 mm screw
Mounting hole for
4×60 mm screw
Locking clip
Locking clip
Cable entry
Mounting hole for
IP board
4×60 mm screw
Thread for M3
securing screw
Fig. 2 BackPlate (top view with IP board)
Ethernet
(RJ45 jack)
Connector for
PTZ dome
Analogue
video preview output
(cinch)
Audio IN
(3.5 mm phone jack)
24/28V AC input terminal
(2-pin Weidmüller male connector)
Fig. 3 IP board
Technical Data
Following technical data was valid at the time of document compilation.
Refer to www.dallmeier.com for possible updates.
Video Preview OUT
1× cinch (CVBS)
Audio IN
1× 3.5 mm phone jack
Ethernet
1× RJ45, 10BASE-T/100BASE-TX
Ethernet Protocols
IPv4, TCP, UDP, ARP, ICMP, DHCP, NTP, HTTP,
RTSP, IGMP V2, RTP, RTCP
Video Buffer
64 MB RAM ring storage
(pre- and post alarm, network failure compensation)
Programming Interface
Open API for 3rd party systems integration via
Dallmeier control for ActiveX (ONVIF conform)
Configuration
IP board:
via web browser
PTZ dome: via web browser,
at the recorder,
via PView
Bubble
Clear or tinted/smoked (note the f-stop reduction)
Voltage Supply
24/28V AC ±10 % (50/60 Hz), 1.0 A
Power Consumption
Max. 24 W
Dimensions
Approx. Ø 155 mm × H 206 mm
Weight
Approx. 1755 g (with PTZ dome camera)
Operating Temperature
−10°C to +40°C
Humidity
0 % to 90 % RH (non condensing)
Approvals/Certifications
CE, FCC, UL, ACA, CB, DIN EN 50130-4 compliant

Werbung

loading

Inhaltszusammenfassung für dallmeier DOMERA DDZ30XX-SM/IP

  • Seite 1 Commissioning All rights reserved. Thread for M3 We reserve the right to make technical modifications. securing screw All trademarks identified by ® are registered trademarks of Dallmeier electronic. Mounting hole for English 4×60 mm screw Mounting hole for All trademarks identified by *) are trademarks or registered trademarks of the following owners: 4×60 mm screw...
  • Seite 2 Inbetriebnahme Alle rechte vorbehalten. Gewinde für M3 Technische Änderungen vorbehalten. Sicherungsschraube Mit ® gekennzeichnete Marken sind eingetragene Marken von Dallmeier electronic. Befestigungsloch für Deutsch 4×60 mm Schraube Mit *) gekennzeichnete Marken sind Marken oder eingetragene Marken folgender Eigentümer: Befestigungsloch für Adobe und Flash von Adobe Systems Incorporated mit Hauptsitz in San José, Kalifornien, USA...