Problem
The mist being
produced is not
warm after pressing
.
Incorrect humidity
level is being
displayed.
Control panel does
not work.
Cause
The humidifier is heating up to
produce warm mist. It will take about
15 minutes after pressing
humidifier to heat up.
Unit has malfunctioned.
Room is larger than the effective
range of the humidifier.
Relative humidity in the room is too
high.
Moisture has built up inside of the
humidity sensor.
The nozzle is facing the direction of
the humidity sensor.
Humidity sensor is broken or
defective.
Hands are too wet when using the
control panel.
Hands are too dry when using the
control panel.
Unit has malfunctioned.
Solution
Please wait for 15 minutes. Use caution
when using the warm mist function. The
for the
mist being produced is 40°C (104°F).
Contact Customer Support (page 33).
Move the humidifier to a room that is
within the effective range of
40–70 m² (430–753 ft²).
If the relative humidity in the room is
over 68% RH, it is recommended to set
the humidifier to the lowest mist setting
or turn off the humidifier.
Turn off the humidifier and allow the
humidity sensor to completely air dry
before resuming use.
Turn the nozzle so that it is facing away
from the humidity sensor.
Contact Customer Support (page 33).
Keep hands dry while operating the
control panel.
Moisturize hands before using the
control panel.
Contact Customer Support (page 33).