INSTALLATION

Installing/Replacing the lamp

The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
During the operation, the lamp reaches temperatures of up to 1000° C.
For the installation, you need one of the following lamps:
OMNILUX OMI 575 95V/575W SFc-10 400h
OSRAM HMI 575/GS 95V/575W SFc-10 1000h
PHILIPS MSI 575 95V/575W SFc-10 1000h
SYLVANIA BA575 DE 95V/575W SFc-10
Procedure:
Step 1: Unscrew the fixation-screws of the lamp protection-cover.
Step 2: Remove the protection-cover.
Step 3: If replacing the lamp, remove the old lamp from the socket.
Step 4: Insert the 95V/575W SFc-10 lamp into the lamp-socket.
Step 5: Replace the protection-cover and tighten the screws.
Mount the SL-575 on the stand.

DANGER TO LIFE!

Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened protection-cover!
17/36
No. 89301005
No. 89301010
No. 89301015
No. 89301020