Herunterladen Inhalt Inhalt Diese Seite drucken

Monacor DMT-2010 Bedienungsanleitung Seite 25

Digital-multimeter
Inhaltsverzeichnis

Werbung

Voltage / Current / Resistance / Capacitance / Frequency
Function
DC voltage
Input impedance 7.8 MΩ
AC voltage
Input impedance 7.8 MΩ
Frequency range 50 – 400 Hz
DC current
AC current
Frequency range 50 – 400 Hz
Resistance
Capacitance
Frequency
Sensitivity > 8 V
All rights reserved by MONACOR
this instruction manual may be reproduced in any form or by any means for any com-
mercial use.
Range
Resolution
400 mV
0.1 mV
4 V
1 mV
40 V
10 mV
400 V
100 mV
600 V
1 V
400 mV
0.1 mV
4 V
1 mV
40 V
10 mV
400 V
100 mV
600 V
1 V
400 µA
0.1 µA
4000 µA
1 µA
10 µA
40 mA
100 µA
400 mA
10 A
10 mA
400 µA
0.1 µA
4000 µA
1 µA
10 µA
40 mA
100 µA
400 mA
10 A
10 mA
400 Ω
0.1 Ω
4 kΩ
1 Ω
40 kΩ
10 Ω
400 kΩ
100 Ω
4 MΩ
1 kΩ
40 MΩ
10 kΩ
40 nF
10 pF
400 nF
0.1 nF
4 µF
1 nF
40 µF
10 nF
100 µF
0.1 µF
5 Hz
0.001 Hz
50 Hz
0.01 Hz
500 Hz
0.1 Hz
5 kHz
1 Hz
50 kHz
10 Hz
500 kHz
100 Hz
5 MHz
1 kHz
10 MHz
10 kHz
Subject to technical modification.
®
INTERNATIONAL GmbH & Co. KG. No part of
Accuracy
±(0.5 % + 2 digits)
±(1.2 % + 2 digits)
±(1.5 % + 2 digits)
±(1.5 % + 70 digits)
±(1.2 % + 3 digits)
±(1.5 % + 3 digits)
±(2.0 % + 4 digits)
±(1.0 % + 3 digits)
±(1.5 % + 3 digits)
±(2.5 % + 5 digits)
±(1.5 % + 5 digits)
±(1.8 % + 5 digits)
±(3.0 % + 7 digits)
±(1.2 % + 4 digits)
±(1.0 % + 2 digits)
±(1.2 % + 2 digits)
±(2.0 % + 3 digits)
±(5.0 % + 7 digits)
±(3.0 % + 5 digits)
±(5.0 % + 5 digits)
±(1.5 % + 5 digits)
±(1.2 % + 3 digits)
±(1.5 % + 4 digits)
GB