MAINTENANCE AND CLEANING

W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
• Before reaching into the water, switch
off the mains voltage of all units in the
water.
• Isolate the unit (disconnect from the
power supply) before carrying out any
work on it.
N O T E
Recommendation on regular cleaning:
• Clean the unit as required but at least
twice per year.
• Do not use aggressive cleaning agents
or chemical solutions as they could at-
tack the housing or impair the function
of the unit.
• Recommended cleaning agent for re-
moving stubborn limescale deposits:
– Pump cleaning agent PumpClean
from OASE.
– Vinegar- and chlorine-free household
cleaning agent.
• After cleaning, thoroughly rinse all parts
in clean water.

WEAR PARTS

The following components are wear parts
and may only be replaced by the OASE
Service.
• Impeller
16
STORAGE/OVERWINTERING
The unit is not frost-proof and has to be
removed and put into storage if minus
temperatures are expected.
How to correctly store the unit:
• Drain the unit as far as possible, clean
thoroughly and check for damage.
• Empty all hoses, pipes and connections
as far as possible.
• Thoroughly clean the unit, check it for
damage and replace any damaged
parts.
• Store the unit in a dry and frost-free
place.
• Protect open plug connections from
moisture and dirt.
DISPOSAL
N O T E
Do not dispose of this unit with domestic
waste.
• Render the unit unusable beforehand
by cutting the cables and dispose of the
unit via the return system provided for
this purpose.