Special mortises
S6 Mortise
For joints with plate thicknesses of over 30 mm, such as
door frames, stairs or bed frames, we recommend using
S6 mortises and proceeding as follows. Set the routing
depth on the adjusting wheel (1) to its maximum setting,
and rout the groove as for standard mortises. Then rout
another groove 10 mm offset from the first one.
H9 Mortise
For frame joints and thin workpieces, we recommend
using H9 mortises. For using this mortise, a special routing
tool (optional accessory) is needed.
Attention!
Before changing routing tools, always pull the mains
plug or remove the mains cable module (17) from the
router housing by releasing the locking button (18).
4
Changing the router
To change the routing tool, loosen the 4 countersunk
screws (19) in the base plate (7) and remove them from the
support shoe (6). Clamp the spindle (21) in place by press-
ing the push plate (20). The flanged nut (22) can be remov-
ed using a double-pin wrench. Remove the old routing tool
(23). Centre the new routing tool on the flange nut (28) and
fasten with the flange nut (22). Then reinstall the base
plate.
Attention!
Observe the direction of rotation of the router!
The routing depth must be checked; adjust as necessary.
Adjusting routing depth
To adjust the routing depth, set the adjusting wheel (1) to
the maximum position. Then push the motor component of
the mortise router forwards as far as it will go. Turn the
routing tool (23) until a cutting tooth (24) has reached the
forwardmost point on the circumference. Use a measuring
rule to measure the routing depth at the routing tool (23).
To correct the routing depth, loosen the nut (25) on the
depth adjustment stop (26). Reset the routing depth by
turning the depth adjustment stop (26) (1 revolution =
0.7 mm). Tighten the nut (25) to fix at the new setting.
Replacing carbon brushes
Our service personnel will do this and all other servicing
work quickly and professionally.
Mains cable
Damaged mains cables must not be used. They are to be
replaced immediately.
This has been made very straightforward by the new mains
cable module (17). Press both locking keys (18) and pull
the mains cable module (17) out of the handle. Insert the
new mains cable into the handle and lock in place. Diffe-
rent lengthed mains cables are available as special acces-
sories.
Only use the mains cable module for KRESS power
tools! Do not attempt to operate other electrical appli-
ances with it!
Motor Cleaning and Maintenance
The powerful universal motor has adequate power re-
serves. To ensure that it has a long service life, blow the
dust out of the blower after each use. Uniform ventilation is
extremely important: always keep the ventilation holes
clean and free of obstruction. The machine is permanently
lubricated and, for the most part, maintenance free.
Tool care
Make sure that only sharp, well-maintained routing tools
are used. This will protect the motor and extend the
service life of the machine. Carbide-tipped routers require
particularly careful treatment, as the cutting edges break
off easily. Damaged routers must not be used.
Noise/vibration information
Values measured in accordance with EN 50144.
Noise level
=
79.5
Noise output
=
92.5
Working
place-specific
emission value
=
82.5
Noise protection measures are required in the interests of
the operator.
The acceleration measured is typically lower than 2.5 m/s
Optional equipment
Router for H9 mortises
Router for routing resin galls
Environmental protection
Kress takes back used machines for resource saving re-
cycling. Due to their modular construction Kress machines
can be very easily broken down into their recyclable basic
materials. Hand in your old Kress machine at a dealer or
send them directly to Kress.
Subject to change without notice.
+3
dB (A)
+3
dB (A)
+3
dB (A).
2
.