C. To perform another measurement, reactivate the laser
beam pressing again the MEAS (measurement) button /
key (12). Then start againg from stage A.
D. When concluding the measurement press the CLR
(clear) button / Off (9) for two seconds to stop the
measurement device.

Measurement of distrance in progress

A. Press MEAS (measurement) / key (12) to turn on the
rangefinder.
B. Press the key for area selection (11) to activate the
area measurement.
C. Aim the laser beam at the first intended point of
measurement (for example, room width) and then press
MEAS (measurement) / key (12) to perform the first
distance measurement.
D. Aim the laser beam at the second point you want to
measure (for example, lenght) and press again MEAS
(measurement) / key (12). The results of width, lenght
and space measurement in sqm are not displayed on
the screen (1).
E. When concluding the measurement press the CLR
(clear) button / Off (9) for two seconds to stop the
measurement device.

Volume measurement

A. Press MEAS (measurement) / key (12) to turn on the
rangefinder
B. Press twice to activate the area selection key (11) to mea-
sure the volume. Display (1) occurs m
3
in lower right corner.
186
C. Aim the laser beam at the first intended point of
measurement (for example, room width) and then press
MEAS (measurement) / key (12) to perform the first
distance measurement.
D. Aim the laser beam at the second point you want to
measure (for example, lenght) and press again MEAS
(measurement) / key (12)
E. When concluding this measurement, set the laser
beam from the third intended point of measurement (for
example, height) and press again MEAS (measurement)
/ key (12). The results of longitude, latitude, altitude and
the volume resulted are displayed on the screen (1) in m³.
F. After the end of measurement press CLR (clear) /
Off (9) for two seconds to turn off the measurement
device.
Indirect measurement of distance –
Pythagora
Remarks!
The device uses Pythagora's theorem to calculate
indirect distances. For distance measurement, the
second laser beam must be aligned to right angles to
the measured line in order to avoid error of results.
Indirect measurement of distance –
with two points
A. Press MEAS (measurement) / key (12) to turn on the
rangefinder.
B. Press three times to activate the key for area selection
(11) to measure the indirect distance. Display (1) a small
187