Herunterladen Inhalt Inhalt Diese Seite drucken

Configuration Of Jumpers - Ecler HMAI80 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10. CONFIGURATION OF JUMPERS

See diagram in section 11. CONFIGURATION DIAGRAM (page 42)
 Phantom Pager/MIC 1/2/3: Phantom power for PAGER / MIC 1/2/3 inputs
 Phantom Emergency: Phantom power for EMERGENCY input
 Control Mode Pager: operation selection of this control port in NO or NC mode
 Control Mode Emergency: operation selection of this control port in NO or NC mode
 Control Mode Mute: operation selection of this control port in NO or NC mode
 Pager Att: attenuation of 20, -30 or -80dB sound sources after activating the PAGER function
 Pager Rec. Time: recovery time of sound source levels after deactivating the PAGER function (1, 2
or 3 seconds)
 24VDC OUT: Emergency: activation of the +24VDC signal after activating the EMERGENCY
function
 24VDC OUT Pager: activation of the +24VDC signal after activating the PAGER function
 Emergency Mode: activation of the EMERGENCY function through automatic signal detection or
dry contact connected to the EMERG control port
 Pager Mode: activation of the PAGER function through automatic signal detection or dry contact
connected to the PAGE control port
 Input Mode: determines whether the signal connected to the EMERGENCY input should work in
EMERGENCY mode or as another input on the mixer (MIC4 or LINE5), with no priority
 High Pass Filter: a high pass filter with a 70Hz cut-off frequency, ideal for optimising audio
performance in high impedance installations
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis