Herunterladen Diese Seite drucken

Relationship To The Authorities; Technical Data - Jøtul F 100 Montageanleitung Mit Technischen Daten

Vorschau ausblenden Andere Handbücher für F 100:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
Table of contents
Installation manual with technical data
1.0
Relationship to the authorities ................... 15
2.0
Technical data ............................................... 15
3.0
Installation ..................................................16
4.0
Service ........................................................... 18
5.0
Optional Equipment .................................... 18
Figures ................................................................... 39
Table of contents
General use and maintenance manual
6.0
Safety precautions
7.0
Choice of fuel
8.0
Use
9.0
Maintenance
10.0
Operational problems - troubleshooting
On all our products there is a label
Product:
Jøtul
indicating the serial number and year.
Room heater fired by solid fuel
Write this number in the place indicated
Standard
:
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
in the installation instructions.
Emission of CO in combustion products
:
Flue gas temperature
:
Nominal heat output
:
Efficiency
:
Operation range
:
Fuel type
:
Always quote this serial number when
Operational type
:
The appliance can be used in a shared flue.
contacting your retailer or Jøtul.
Country
Classification
Certificate/
Approved by
standard
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
SP Swedish National
Testing and Research
EN
EUR
Intermittent
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those which refer to national
and European standards, must be observed when installing the
product.
Both an installation manual with technical data and a manual
on general use and maintenance are enclosed with the product.
The installation can only be used after it has been inspected by
a qualified inspector.
A name plate of heat-resistant material is affixed to the
product. This contains information about identification and
documentation for the product.

2.0 Technical data

Material:
Finish:
Fuel:
Log length, max.:
Flue outlet:
Flue pipe dimension:
- inside :
- outside :
Approx. weight:
Optional equipment:
Dimensions, distances etc.:
Technical data according to EN 13240
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught:
Efficiency:
CO emission (13% O
):
2
Flue gas temperature:
Operational mode:
Intermittent combustion in this context means normal use of the
fireplace, i.e. fuel is added as soon as the fuel has burnt down to
a suitable amount of embers.
ENGliSh
Cast iron
Enamel or black paint
Wood
40 cm
Top and rear
Ø125 mm/123 cm
cross
2
section
Ø 150mm/177 cm
cross
2
section
97 kg
Enamelled floor plate,
long legs, extra heat shield
See fig. 1
5,5 kW
5,0 g/sec
12 Pa
78%@6,1 kW
0,18%
298
C
o
Intermittent
15

Werbung