The network switch can be configured via the integrated Web interface. The standard IP-
Address is 192.168.2.1; the user name and the password are both "admin".
To carry out the configuration via the Web interface, you must first assign the LAN connection
for your PC a fixed IP address. This should be something like 192.168.2.x, where x can be
between 2 and 254. Set the subnet mask to 255.255.255.0. Please, also refer to the instructions
for your operating system. The computer you want to run the configuration on needs to be
directly connected to the switch.
As soon as the network connection is complete, open your Web browser and enter
http://192.168.2.1/ in the address line. The login page for the Web interface should now appear.
Enter "admin" as both the username and password here.
The home page for the web server will then appear, from which all of the settings can be made.
Please consult the manufacturer's English instruction manual.
If this is enclosed in PDF format on a CD, you will need "Adobe Reader" to read it;
this can be downloaded for free from www.adobe.com.
PoE+ (Power over Ethernet)
The network switch provides PoE on the network ports 1 to 8. An end device, such as a network
camera that supports PoE, is thus automatically provided with power over the network cable.
This has the advantage of allowing only one cable to be used for both data transfer and power
supply to the device.
Please note:
The permitted power consumption of 30 Watt per port must not be exceeded! Consult
the technical data for the products to be connected.
In every case, use a fully wired network cable for connecting a PoE device. We
recommend the use of a cable with the specification of CAT5e or better.
Please observe the operating instructions of the device in question.

Resetting to Factory Settings

On the front, on the left, next to the LEDs, a countersunk reset button can be found, with which
the switch can be reset to the factory settings.
Connect the switch to the mains voltage, if it has not already been done. Wait about 20 seconds
until the self test has finished. Then press and hold the "Reset" button for 5 seconds and then
release it.
The switch restarts, this takes about 20 seconds. The switch is then reset to the factory settings
(IP address 192.168.2.1; username and password "admin").
Handling
• Use only in dry indoor locations. The product must not get damp or wet! There is
risk of an electric shock!
• Never use the product immediately after it has been taken from a cold room to a
warm one. The condensation that forms might destroy your unit. There is also risk
of an electric shock!
Allow the product to reach room temperature, before connecting it to the power
supply and putting it in to use. This may take several hours.
• Any maintenance or repair work may only be performed by an authorised repair
shop.
• Check the product for damage before each use!
If you detect any damage, do NOT connect the unit to the mains voltage! This
presents a danger to life!
• It can be assumed that safe operation is no longer possible if:
- the product shows visible signs of damage,
- the product does not function or does not function properly (e.g. a burning smell)
- the product was stored under unfavourable conditions
• When setting up the product, make sure that the cables are neither kinked nor
pinched.
• If you are not going to use the product for a while (e.g., during storage), disconnect
the power plug from the mains socket (all the network connections will cease to
function!)
• Avoid the following unfavourable environmental conditions at the installation
location or during transport:
- Excessive humidity or damp
- Extreme cold or heat, direct sunlight
- Dust or flammable gases, fumes or solvents
- Strong vibrations, impacts or blows,

Maintenance and Cleaning

The product does not require any maintenance and should never be disassembled for any
reason.
Disconnect the product from the power supply before cleaning, unplug the mains plug from the
mains socket (all network connections will cease to function).
Dust can easily be removed using a clean, soft brush and a vacuum cleaner.
Do not use aggressive cleaning agents as these can cause discolouration.
Do not press too strongly on the surface, to prevent scratch marks.
Tips & Notes
• If you have your own network or system administrator for your network (as will probably be the
case in a larger company), please let this person assume the responsibility for connection and
wiring. Do not connect the switch yourself!
• The twisted-pair cable (also called a patch cable) between the switch and the device to be
connected should have a max. length of 100m. Use only so-called CAT5e cables that are fully
wired (all 8 contacts of the RJ45 connector are connected 1:1).
• The type of cable to be used with your SFP module (not included in the delivery, it has to be
ordered separately) can be found in the SFP module's instructions (or e.g. on the manufacturer's
website). The same applies to the maximum possible cable length.
• The maximum theoretical data transfer rate of 10, 100 or 1000MBit/s is usually not achieved
in practice (e.g. 1000MBit = approx. 125MByte/s) During data transmission, not only data, but
also protocol information etc is transmitted, data packages must be repeated or different
computers may want to transmit data at the same time.
• If the switch is not supplied with power, all the connections will be out of operation. A network
connection is not possible.
• Before the SFP module can be connected to or disconnected from the network switch, the
switch must first be disconnected from the mains voltage.
Disposal
Electrical and electronic products do not belong in the household waste!!
Please dispose of the device when it is no longer of use, according to the current
statutory requirements.

Technical Data

Operating voltage ................................100 - 240 V/AC, 50-60 Hz
Input: ....................................................Max. 260 W
Network ports ......................................8 ports for 10/100MBit with PoE+
PoE outgoing current............................48 V/DC per port
PoE power consumption ......................Max. 30 W per port
Dimensions (W x H x D) ......................Ca. 440 x 44 x 221 mm (without feet, without SFP
Weight ................................................Approx. 3.125 kg
Operating ambient temperature ..........0°C to +55°C
Humidity during operation ....................10% to 90% relative air humidity, not condensing
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2011 by Conrad Electronic SE.
2 combination ports for 10/100/1000MBit or optionally
2 SFP modules (not included)
module)