Automatic mode ProMax ClearDrain
11000/14000
The pump switches on when the rising wa-
ter reaches the sensor.
Metal contacts at the bottom of the sensor
strip detect the minimum water level
(switch-off point). When the minimum wa-
ter level is reached, the pump switches off.
 E
• Fit the sensor onto the sensor strip in
the desired switch-on position.
Manual mode ProMax ClearDrain
11000/14000
The pump remains permanently switched
on when the sensor is located in the top
position.
N O T E
The pump can run dry in manual mode.
• Switch off the pump when the minimum
water level is reached.
• Running the pump dry increases wear.
 F
• Fit the sensor onto the sensor strip in
the top position.
Setting the residual water level
The pump can pump the water down to a
depth of 6 mm to 8 mm or down to 1 mm.
 G
• Residual water level 6 ... 8 mm: Fit the
spacer ring and secure with the retain-
ing ring (bayonet closure).
• Residual water level down to 1 mm
(shallow extraction): Release the retain-
ing ring (bayonet closure) and remove
the spacer ring.
14
N O T E
Shallow extraction is only possible in
manual mode.
Installing the pump
 H
• Install the pump in a horizontal and sta-
ble position in the water.
• If it needs to be lowered into a well or a
shaft, fasten a rope to the handle. Do
not carry it by the power connection
cable.
• Install the pump such that it does not
take in dirt particles with a size >5 mm,
which would block the intake. Install the
pump in a raised position if necessary.
• ProMax ClearDrain 7000: Ensure that
the float switch can always move freely.
OPERATION
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
• Only connect the pump to the power
supply when there are no persons in or
reaching into the water.
• Before stepping into or reaching into the
water, switch off all units located in the
water.
Switching on the unit
• Insert the power plug into the socket.
– The pump is ready for operation.
– The pump will start up as soon as the
level of the water reaches the switch-
on height.
ProMax ClearDrain 7000/11000/14000