Herunterladen Inhalt Inhalt Diese Seite drucken

Modbus Plus Option - Mettler Toledo PANTHER Installationsanleitung

Vorschau ausblenden Andere Handbücher für PANTHER:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 64

Modbus Plus Option

There are two connections for the Modbus Plus Interface.
The standard connection for the PANTHER panel-mount terminal is the DE-9 female
connector. Wiring instructions come with the connector. The Modbus Plus network
uses pins 1, 2, and 3 of the DE-9 connector (supplied by Modicon).
The PANTHER harsh environment terminal must use a pluggable terminal strip.
When the terminal strip is used, the Modbus Pigtail Cable kit 0900-0320 is
available.
The Modbus Plus pigtail is wired to the PANTHER terminal as follows:
DE-9
1
2
3
Chapter 3: Installing/Wiring Option Cards
PIN 1
Terminal Strip
White
Green
Black
Modbus Plus Option
1
2
3
(7/03) 3-3