10. Disposal

Electric and electronic products must not be disposed of in the
domestic waste.
At the end of its service life, dispose of the product according to
the relevant statutory regulations.

11. Technical data

Operating voltage:
Adjustable temperature range:
Relay capacity:
Switching threshold:
Temperature sensor:
Operating temperature range:
Relative air humidity:
Dimensions (LxWxH):
Weight:
26
230 V/AC, 50 Hz
+5°C to +30°C (continuously adjustable)
max. 230 V/AC , 50 Hz, 6(2)A (this product is
only suited for resistive consumers. You may
not connect any inductive consumers).
ca. 1°
NTC Thermistor
0°C to +40°C
10% to max. 80% uncondensed (no steam)
approx. 75 x 75 x 30 mm
ca. 78 grams