Herunterladen Inhalt Inhalt Diese Seite drucken

General Notes - Maico WR 310 Installationsanleitung

Vorschau ausblenden Andere Handbücher für WR 310:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

170
Unit types
K
PTC heat register
B
Bypass
ET Enthalpy heat exchanger
Unit types
K
WS 170 KBR
WS 170 KBL
WS 170 KBRET
WS 170 KBLET
RB 170 CBR
RB 170 CBL
Flat
Unit types
K
PTC heat register
B
Bypass
Z
Zone shutter
ET Enthalpy heat exchanger
Unit types
WS 160 Flat ET
WS 160 Flat KET
WS 160 Flat BET
WS 160 Flat KBET
WS 160 Flat KBZET
Trio
Unit types
L
Ventilation unit through which air flows
lengthwise
Q
Ventilation unit through which air flows
crosswise
Z
Central unit
D
Decentralised unit (1 unit/room)
AL Exhaust air left
AR Exhaust air right
Unit types
central
Trio
QZ AR *
QZ AL *
LZ *
QD AR **
QD AL **
* All connection sockets can be fitted in
3 positions (face end, lengthwise or
through the unit base).
B
ET
Article no.
0095.0087
0095.0088
0095.0114
0095.0115
0040.0087
0040.0088
K
B
Z ET Article no.
0095.0090
0095.0091
0095.0092
0095.0093
0095.0094
decentra-
Article no.
lised
GVT10010005
GVT10010010
GVT10020005
GVT10020015
GVT10020020
** Connection sockets of external and
outgoing air can be fitted lengthwise
on the unit base

5 General notes

5.1 Qualifications of specialist installer
The ventilation unit may only be installed, set
up, retrofitted, started up, cleaned and main-
tained by a trained specialist in accordance
with these instructions.
You are considered a trained specialist if your
specialist training or experience in ventilation
technology
● enables you to correctly and safely under-
take installation in accordance with the plan-
ning documents and these instructions and
● you are able to recognise and avoid risks
resulting from incorrect installations and
settings and the resultant hazards.
Only a trained electrician is permitted to work
on the electrics. You are considered a trained
electrician if your specialist training and
experience
● means that you are familiar with the relevant
standards and guidelines
● enables you to correctly and safely under-
take the electrical connections in accord-
ance with the wiring diagram provided and
● enables you to recognise and avoid risks
and hazards associated with electricity.
After successful installation and commis-
sioning, instruct users in the ventilation
unit and operating units.