The measurement takes place at the middle point of the light spot,
also for obliquely illuminated target surfaces.
The measuring range is dependent on the light relationships and the
reflection characteristics of the measured surface. For working in ex-
terior areas and with strong direct sunlight, use the optical sight ZO 4
30, the laser viewing glasses 28 and the target panel 29 (accessory)
for better visibility of the laser point or shield the target surface.
When measuring to transparent surfaces (e.g. glass, water) or reflect-
ing surfaces, erroneous measurement can result. Porous or struc-
tured surfaces, air strata with different temperatures or indirectly re-
ceived reflections can also influence the measured value. These
effects are caused by physical properties and can therefore not be ex-
cluded by the measuring instrument.
In the dark, press the display lighting button
lit. To switch off the lighting, press the
By means of the upper and side aligning aids 4, aiming over longer
distances is facilitated. For this purpose, sight along the upper or side
aligning aids. The laser beam runs parallel to these lines of sight (see
Fig.
).
A
When the DLE 150 Connect is switched off, all values in the memory
of the unit are retained. However, when the end piece is removed
(changing of the end piece or the batteries), the memory contents are
lost.
Changing the End Piece
The unit is provided with two different end pieces.
The compact end piece 17 reduces the dimensions of the unit. It is suit-
able for measurements for which the rear end of the unit can rest on a flat
surface.
The universal end piece 18 is suitable for measurements from corners,
e.g. to determine the diagonals of a room.
With the aid of the positioning extension 27 on the universal end piece
18, the unit can be placed on an edge (see Fig.
pull up the flap 25 with the grips 24 and fold out the positioning ex-
tension 27.
If the rear end of the unit is to be placed on a flat surface, fold in the
positioning extension 27.
For measuring from corners, fold in the positioning extension 27,
press the unlocking button 26 and allow the flap 25 to relatch.
To change the end piece, press the latches 19 on both sides and remove
the end piece. Insert the new end piece.
The unit takes automatically into consideration the different lengths of the
end pieces when measuring (measurement in both cases from the rear
end of the unit).
Bubble Level
The bubble level makes possible the easy horizontal alignment of the unit.
The bubble level 3 can be attached on the right or left of the display 8 on
the housing. Attach the bubble level with the lower end of the holder first.
Measurements with a Tripod
Measurements with a tripod are especially necessary for long distances.
The unit can be screwed onto a camera tripod with the 1/4" threads 20
on the underside of the housing.

Also with the use of a tripod, the unit measures from its rear
end and not from the middle of the threads.
The distance from the threads 20 to the rear edge of the unit is 45 mm
with the compact end piece 17 and 70 mm with the universal end piece
18.