Herunterladen Diese Seite drucken

HP SureStore Plattensystem 2100 Benutzerhandbuch Seite 25

Werbung

%HLVSLHOEHQDFKULFKWLJXQJEHU+DUGZDUHHUHLJQLVVH
$EELOGXQJ
Notification Time:
yourserver sent Event Monitor notification information:
/storage/events/disks/default/10_4_4_0.0 is >=1.
Its current value is CRITICAL(5)
Event data from monitor:
Event Time: Wed Feb 3 11:27:15 1999
Hostname: yourserver.rose.hp.com
Event ID: 0x0036b8a313000000002
Event # : 100037
Severity : CRITICAL
Disk at hardware path 10/4/4/0.0 : Media failure
Associated OS error log entry id(s) : 000000000000000000
Description of Error:
The device was unsuccessful in reading data for the current I/
O request due to an error on the medium. The data could not be
recovered. The request was likely processed in a way which
could cause damage to or loss of data.
Probable Cause / Recommended Action:
The medium in the device is flawed. If the medium is removable,
replace the medium with a fresh one. Alternatively, if the
medium is not removable, the device has experienced a hardware
failure. Repair or replace the device, as necessary.
+36XUH6WRUH3ODWWHQV\VWHP
Wed Feb 3 11:27:15 1999
IP Address : 15.43.213.13
Monitor
Event Class: I/O
: disk_em


Werbung

loading