1 Operating Elements and Connections

1.1 Front
1 Opening for the integrated microphone
2 Fixed focus lens
3 PIR motion detector (passive infrared);
automatic start of the camera and the transmitter
in case of a recognized movement if the sliding
switch (8) is in the position "Trigger"
4 Camera part
5 Transmitting part
6 Jack for power supply via the delivered power
supply unit
7 3.5 mm jack to activate the automatic start via a
normally open (NO) contact or via a control volt-
age of 5 V~ to 30 V~
1.2 Rear
8 Mode selector switch
Trigger the camera and the transmitter are auto-
matically switched on when a movement
is recognized
OFF
the unit is completely switched off
ON
the camera and the transmitter are per-
manently switched on
9 Control "Time" to adjust the tracking time in case
of activated automatic start (2 s to 5 min)
10 Setscrew for horizontal orientation when using the
camera as a table top unit or for slightly turning the
unit in case of wall mounting
11 Rotary switch "Channel" to adjust the transmis-
sion channel
Pos.
Channel
0, 1
1
2
2
3
3
4
4
5
5
6 ... F
1
12 Mounting holes to attach the unit to a wall
13 Recess to accommodate the antenna if the
camera part and the transmitting part are placed
separately
2
Safety Notes
The camera and the power supply unit correspond to
the
directive
for
electromagnetic
89/336/EEC. The power supply unit also corre-
sponds to the low voltage directive 73/23/EEC.
The power supply unit is supplied with hazardous
mains voltage (230 V~). Leave servicing to skilled
personnel only. Inexpert handling may cause an
electric shock hazard. Furthermore, any guarantee
claim will expire if the power supply unit has been
opened.
The camera and the power supply unit are suitable
for indoor use only. Protect them against humidity
and heat (admissible ambient temperature range
0 – 40 °C).
Do not operate the camera or immediately dis-
connect the power supply unit from the mains
socket
1. if there is visible damage to the camera or to the
power supply unit,
2. if a defect might have occurred after the unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by skilled per-
sonnel.
For cleaning only use a dry, soft cloth, by no means
chemicals or water.
If the units are used for other purposes than orig-
inally intended, if they are not correctly connected
or operated or not repaired in an expert way, no
liability for any damage will be accepted.
If the units are to be put out of operation definitively,
take them to a local recycling plant for disposal.
3
Applications
In combination with a 2.4 GHz receiver of the
MONACOR "AV-..." series and a monitor, the wireless
B/W camera with integrated electret microphone
serves for wireless audio and video surveillance. The
camera is equipped with a motion detector which
switches on the camera and the integrated transmit-
ter for a certain time upon recognition of a movement.
The transmission range largely depends on the
local conditions and the receiver used. In case of
visual contact between transmitter and receiver, it can
be up to 750 m, but in buildings it is reduced by walls
and ceilings to approx. 50 m according to their condi-
tion. However, by using an antenna with gain at the
receiver, the range can be increased many times
over.
3.1 Approval
The camera has been approved by the German
federal office for telecommunications approval (BZT)
under the number G750 634G for operation in the
Federal Republic of Germany. For operation in other
countries, please contact your retailer or the
MONACOR subsidiary in the country where this
camera will be operated.