Herunterladen Inhalt Inhalt Diese Seite drucken

Switching To Another Type Of Gas - Salvis Gas-Char Grill 400 Betriebsanleitung

Profiline
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9.

Switching to another type of gas

Observe the notes regarding safe operation, refer to page 29 Chapter 2.
● Only use original nozzles when switching to another type of gas.
. After switching to another type of gas and after maintenance tasks:
− Check all parts carrying gas for tightness (leak spray).
− Install identification of the type of gas and gas supply pressure at the appliance, refer to
page 43 Chapter 9.5.
. Allocate and determine the nozzles and settings required, refer to the following chapter 9.1
DANGER! Risk of explosion!
. Before assembly and conversion tasks, close the gas tap on the appliance and on
site!
. Lock the on-site gas tap against unintentional opening!
. Place a sign at the on-site gas tap to indicate that work is in progress on the gas
system!
en
39 / 52

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gas-char grill 800Gas-char grill 1200

Inhaltsverzeichnis