5.2

Settings

To get to the setup menu, press the ENTER key (6) until the first digit flashes. Then enter "888".
With the Arrow right key (7), you can navigate through the digits and change the value of the digit
with the Arrow up key (8). Confirm with ENTER (6).
The following options can be selected using the Arrow up key (8):
Display
Meaning
Ext
Exit
S1
Pre-alarm
S2
Alarm
Flt
Filter
Str
Factory settings
To enter the relevant menu, select the menu with the Arrow up key (8) and confirm with ENTER
(6).
You can leave the menu by selecting "Ext" and confirming with the ENTER (6) key. If no key is
pressed for 60 seconds, the device enters normal measuring mode automatically.
Description
Back to normal measuring mode
Enter the desired value (max. 50 m/s). You can move the
cursor with the Arrow right key (7) and change the value of the
digits with the Arrow up key (8). Confirm with ENTER (6).
Please note:
The pre-alarm value must not be higher than the alarm
value and the alarm value must not be lower than the pre-
alarm value.
Enter the desired value (max. 50 m/s). You can move the
cursor with the Arrow right key (7) and change the value of the
digits with the Arrow up key (8). Confirm with ENTER (6).
Please note:
The pre-alarm value must not be higher than the alarm
value and the alarm value must not be lower than the pre-
alarm value.
You can use the Arrow right key (7) to navigate through the
digits and the Arrow up key (8) to change the value of the
digits. Confirm with ENTER (6).
The following options can be selected:
"000" Current wind speed
Change interval of display:
Change interval of relay:
"002" 2-minute average value
Change interval of display:
Change interval of relay:
"005" 5-minute average value
Change interval of display:
Change interval of relay:
Resets all parameters to factory settings
© PCE Instruments
28
200 ms
200 ms
120 s
120 s
300 s
300 s