Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Sensors; Operation; Measurement - Pce Instruments Pce-Wsac 50 Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

4.3

Connecting the sensors

Connect the sensor (not included in the standard package) and the (optional) interface, using the
plugs as described in 3.3 and 3.4. Make sure that the polarity and the power supply are correct.
ATTENTION: Non-observance of the polarity can destroy the wind speed alarm
controller and the sensor.
5

Operation

5.1

Measurement

The device measures continuously as long as it is connected to the power supply. The factory
default setting for the pre-alarm (S1) is from 8 m/s and for the alarm (S2), the default setting is
from 10.8 m/s.
The pre-alarm will make the pre-alarm relay switch, a yellow LED will glow and a beep sound will
be emitted in intervals.
In case of an alarm, the alarm relay will switch, the red LED will glow and a continuous beep
sound will be activated.
© PCE Instruments
27
Inhaltsverzeichnis
loading

Inhaltsverzeichnis