3. Adjustable parameters

(Menu structure: see fold out page)
Switch-on point: Upper limit value at which the output changes
its switching status.
• adjustable in steps of 1% of the value of the measuring range
• setting range 5 ... 100% of the value of the measuring range
• indicated in bar
Switch-off point: Lower limit value at which the output
changes its switching status.
• adjustable in steps of 1% of the value of the measuring range
• setting range: 3 ... 99% of the value of the measuring range
• indicated in bar
SP1 is always higher than rP1. The unit does not accept values
for rP1 which are higher than SP1.
Changing the switch-on point also changes the switch-off point
(the distance between switch-on point and switch-off point
remains constant).
If SP1 is set to the minimum value and then increased, rP1 is
also set to the minimum value and increased proportionally.
Delay time for SP1, rP1:
The output does not immediately change its switching status
when the switching condition is met but when the delay time
has elapsed. If the switching condition is no longer met when the
delay time has elapsed, the switching state of the output does
not change.
• adjustable in steps of 0.2 or 1s
• setting range: 0 - 0.2 - 0.4 ... 9.8 - 10 - 11 - ... - 49 - 50s
• indicated in seconds
Switching functions of the switching output:
4 settings can be selected:
= hysteresis / normally open
= hysteresis / normally closed
= window function / normally open
= window function / normally closed
17