Trouble shooting / En cas... de non fonctionnement
This power amplifier has protection features to prevent any damages from misuse or faulty conditions. If the unit
senses excessive heat, short circuited speakers or overload, the protection indicators will light, and the system
will be turned off. In order to check the occurred problem, you should turn all levels down and all power off and
carefully check the installation for wiring mistakes or short. If the amplifier shuts down due to excessive heat, the
protection indicators will not light: simply allow time for the unit to cool. Before removing your amplifier, refer to
the list below and follow the suggested procedures.
Always test the speakers and their wires first.
Problem
Amplifier is
not powered up
Protection LED illuminates
when amplifier is powered
up
Fuse blowing
Overheating
Sound too low / Distorted
sound
High hiss /
engine noise
in speakers
Cette amplificateur et équiper de protection pour éviter tous dégâts en cas de mauvaise manipulation .Si l'ampli
détecte une anomalie (court-circuits – surchauffe ) l'ampli se coupe automatiquement . Pour examiner le
problèmes vérifier tous vos branchements , le temps que l'ampli refroidisse . vérifier en premier les Haut parleurs
puis tous les câbles d'alimentation . si le problèmes persiste consulter un technicien.
Problèmes
Contrôle
Voyant PWR allumé?
Pas de son
Le Voyant PROTECTION
est allumé ?
Amplificateur ne
Pas d'alimentation
se met Pas en
Pas d'alimentation sur le
marche
REMOTE
Ampli se met en
Vérifier l'Impédance des
PROTECTION a
Haut-parleurs
haut Volume
Pas de son sur 1
Vérifier câble RCA et ou
canal
câble Haut-parleurs
Check points
•
Check that there is battery power on the +12V terminal.
•
Check that remote terminal has at least +12V DC remote connection.
•
Check a good ground connection. Check all fuses.
•
Check the protection LED is not lit.
•
Check shorts on speaker wires.
•
Remove speaker wires and reset the amplifier. If the protection LED still comes on,
then the amplifier is faulty.
•
Check that the minimum speaker impedance is correct.
•
Check short on power cable and vehicle chassis.
•
Check that the minimum speaker impedance is correct.
•
Check speaker shorts.
•
Check that there is a good airflow around the amplifier.
•
Check that the input level control is set to match the output level of the unit.
•
Check the head unit volume.
•
Check speaker shorts.
•
Check that crossover frequencies have been properly set.
•
Check a good ground and for speaker shorts.
•
Disconnect all RCA inputs from the amplifier. If hiss/noise disappears, check it with
a good RCA interconnect. Then check the component driving the amplifier.
Aide
•
Vérifier le fusible, Contrôler le Câble REMOTE, Contrôler
le+12Volt et la masse
•
Court circuit des Haut-parleurs, ampli surchauffe ou défectueux
•
Vérifier le + 12 volt, la masse, le fusible
•
Vérifier le REMOTE sur l'Autoradio
•
Vérifier si l'Impédance sur les connecteurs des haut-parleurs n'est
pas en dessous de 2Ω
•
Vérifier si l'Impédance sur les connecteurs des haut-parleurs n'est
pas en dessous de 1Ω
•
Câble ou prise (RCA) défectueux