button, where you want to copy to, then press the ENTER button to save the scene. If the edition is
completed, you can log off by pressing the ESC button.
Saving the program:
When pressing the ESC button, the controller asks for the confirmation to save the modification. Be aware
that the program written will consist of as many steps as the serial number of the last scene saved at
indicates!
Program deletion:
The program can be deleted in the program selection by pressing the DELETE (LEFT) button. The controller
asks for the confirmation to delete, after clicking on the YES button, it will complete it. Thus the scenes of the
programs allocated by the program are released.
Program copy:
Events can be copied to vacant places. This could be reasonable if you want to use several events which
have only a few differences. In this case create the first event, then copy it to a vacant place, and then
modify it.
First select the event which you would like to copy, and press the NEW button. Its LED starts blinking and on
the lower line of the display you can read the text to be copied. Select a vacant place with buttons 1-16
where you would like to copy the event to. The display shows the info about source and destination places. If
you press ESC the controller return without copying, press ENTER to copy the event.
MENU 3: SEQUENCE EDITION
The sequence is an event, which affects the strobo channel of the units, it closes and opens the strobo
channel. Moreover it is possible to program which unit should be closed or open at which time while
programs can be run on them.
The 64 sequences to be run by the controller can be written in this menu item, the existing one can be edited
or deleted. The maximum step number of a sequence is 16 steps.
In the upper line the number of the selected sequence, or if it has been written, its step number, if it has not
been written, 'free' caption appears. In the lower line the sequence name appears if the sequence has been
written.
Select a sequence with buttons 1-16 and the PAGE shifting button. If you want to select units 1-10, you do
not have to press all 10 buttons, simply keep button 1 pressed and then press button 10. By pressing
ENTER you can move to the sequence edition.
Sequence name specification:
Name the sequence, then press ENTER.
Sequence masking:
51/62